DIMENSIONS

6"WX12"LX4.5"H (152mmW X 305mmL X 114mmH)

WEIGHT

1.5 lbs (680 g) 

COLOR

YELLOW

FACEPLATE

1/8" (3.175mm) ALUMINUM

MOISTURE

IP66 WEATHERPROOF

TEMPERATURE

-5°F TO 158°F  (-20° TO 70°C)

BATTERY STANDARD

3 X AAA CELLS (STANDARD ALKALINE)

BATTERY LIFE (TYPICAL)

3 MONTHS

POWER

ON/OFF

HORN

ON/OFF

SENSITIVITY

LOW, MEDIUM, HIGH 

INDICATOR VISUAL

RED LED 

INDICATOR AUDIBLE

HORN

INDICATOR BATTERY

"LOW BATT" DISPLAY

CALIBRATION

FACTORY SEALED (NO CAL RECAL REQUIRED)

PROBE

MODEL

RP-20203-N  N=LENGTH

MOISTURE

IP68

TEMPERATURE

15°F TO 140°F  (-9° TO 60°C)

MATERIAL

STAINLESS STEEL

TECHNOLOGY

IRED EMITTER/DETECTOR

SENSOR GAP

0.78"  (20MM)

LENSES

POLYCARBONATE CLEAR

RANGE MIN

100-2000 mg/l (varies)

RANGE MAX

100-10000 mg/l (varies)

DIMENSIONS

2.5"WX3.5"LX.75"H  (64mmW X 89mmL X 19mmH)

WEIGHT

1 lb (450 g)

COLOR

SILVER

CABLE

MOISTURE

IP68

TEMPERATURE

15°F TO 140°F  (-9° TO 60°C)

LENGTH

20 TO 50FT (6.1M TO 15M)

REPLACEMENT PARTS

CABLE ASSY WITH PROBE

RP-20200-N  WHERE N = LENGTH

Pg 2

SLUDGE INTERFACE DETECTOR SID-20200   SPECIFICATIONS

HANDHELD UNIT

QUICK CHECK

Press POWER button.

Press HORN to button to enable.
Place your finger over a probe sensor len.
The INTERFACE lamp illuminates and horn sounds.

The horn can be switched-off without affecting unit operation.

BATTERY REPLACEMENT

Batteries are located inside the case head.
Remove the case faceplate four screws.

Remove the faceplate from the case and leave wire attached.
Slide the black battery pack out of the case holder.
Remove battery pack cover.

Replace all three AAA batteries with new alkaline batteries.
Slide the black battery pack into the case holder.

Install case faceplate with original screws snug tight.

SENSOR ADJUSTMENT

SENS "LOW" - Detects large solids only
SENS "MED" - Detects intermediate and larger solids
SENS "HIGH" - Detects all solids

FINE TUNING SLUDGE DETECTION

When

you’ve

established a baseline sensitivity for a tank, you can fine-tune by

increasing and decreasing the sensitivity above your baseline.

At sensitivities higher than your baseline, you can detect the ragged edge on top of
the sludge blanket.

Sludge blankets rarely have a well defined interface with the supernatant.
Experience with the

SENSOR ADJ

will allow the keen operator to measure the

ragged edge of the sludge blanket. It is not uncommon in a dynamic environment
such as a secondary clarifier to identify several feet of gradual density change on top
of the sludge blanket.

CABLE REPLACEMENT

The cable and probe are one assembly and can be replaced in the field.

Contact Raven for replacement parts and probe assemblies.

DESIGNED AND MANUFACTURED IN USA BY