27
APPENDIX 3
ALTERNATE BY-PASS LINE PLUMBING SYSTEM
FIGURE 11
FIGURE 11
FIGURE 11
FIGURE 11
FIGURE 11
INITIAL SYSTEM SET-UP
Plumb the system as shown in Figure 11.
Adjust as follows:
Install Polarity Reversal Jumper in motorized Control Valve Cable (P/N 115-0159-415).
1)
1)
1)
1)
1)
Fill tank with water only.
2)
2)
2)
2)
2)
Place MASTER ON/OFF switch to ON and BOOM ON/OFF switches to OFF.
3)
3)
3)
3)
3)
Place AUTO/MAN/OFF switch to MAN.
4)
4)
4)
4)
4)
Verify that Boom Widths, SPEED CAL, METER CAL, and RATE CALS have been entered
correctly into the Console. In SELF TEST mode enter the normal sprayer operating
speed.
5)
5)
5)
5)
5)
With pump not running, fully open main line hand valve, fully open by-pass #1
hand valve, and completely close agitator line hand valve. If positive
displacement pump is used, fully open the pressure relief valve (PRV).
6)
6)
6)
6)
6)
Run pump at normal operating RPM.
7)
7)
7)
7)
7)
If centrifugal pump is used, proceed with Step 8. If positive displacement pump
is used, proceed as follows:
a)
Place MASTER ON/OFF switch to OFF.
b)
Close by-pass #1 hand valve.
c)
Set PRV to 65 psi [450 kPa].
d)
Open by-pass #1 hand valve.
e)
Place MASTER ON/OFF switch to ON.