Initial Machine Calibration: Initial Machine Calibration
19
INITIAL MACHINE CALIBRATION
RESUME AND DISENGAGE SWITCH CALIBRATION
FIGURE 17. Resume Switch Verification Screen
1. Press the foot/resume switch. The switch status icon will change if the switch input is detected and the
calibration will automatically proceed to the next screen.
NOTE:
Select the
Use On-Screen Engage
option to use an on-screen engage widget to start and stop auto-
steering during SC1/TC1 operation.
FIGURE 18. Disengage Switch Calibration Screen
2. Turn the steering wheel to calibrate the disengage sensor. The status icon will change if the input is detected
and the calibration with automatically proceed to the next screen.
NOTE:
In a SmarTrax MD/HD system, a screen displaying the calibrated disengage value will be displayed.
This value is editable.
WHEEL ANGLE SENSOR (WAS) CALIBRATION
NOTE:
The machine must remain moving during the WAS calibration.
Содержание SC1
Страница 8: ...CHAPTER 1 4 Raven SC1 TC1 software version 1 5 Calibration Operation Manual for Towed Implements...
Страница 12: ...CHAPTER 2 8 Raven SC1 TC1 software version 1 5 Calibration Operation Manual for Towed Implements...
Страница 30: ...CHAPTER 3 26 Raven SC1 TC1 software version 1 5 Calibration Operation Manual for Tractors and Sprayers...
Страница 40: ...CHAPTER 4 36 Raven SC1 TC1 software version 1 5 Calibration Operation Manual for Tractors and Sprayers...
Страница 54: ...CHAPTER 5 50 Raven SC1 TC1 software version 1 5 Calibration Operation Manual for Tractors and Sprayers...
Страница 76: ...CHAPTER 8 72 Raven SC1 TC1 software version 1 5 Calibration Operation Manual for Towed Implements...
Страница 81: ...77 FIGURE 10 Port B Configuration 7 Press Enter to save the settings...
Страница 82: ...CHAPTER 9 78 Raven SC1 TC1 software version 1 5 Calibration Operation Manual for Tractors and Sprayers...
Страница 86: ...Index 82 Raven SC1 TC1 software version 1 5 Calibration Operation Manual for Tractors and Sprayers...