2.3
INSTALLING THE CABLE HARNESSES
Both the CAN basic harness and the CAN implement
ready harness are divided into the following harnesses
(in order from the battery):
1.
Power harness: an Implement Ready power
harness is mounted from the battery to the
IBBC connector at the back of the tractor. A
Basic power harness is mounted from the
battery to the STU SmarTrax MD Harness.
Make sure that the relays and fuses are
mounted in a dry, clean and accessible spot
(Figure 3).
2.
Extension Harness: this harness is connected
with the power harness and the In-Cab
DynamIQ harness. A branch is made to the STU
SmarTrax MD Harness. This harness is wrapped
in a hard casing.
3.
STU SmarTrax MD Harness: this harness is
connected with the extension harness. Connect
the STU, the wheel angle sensor cable and the
Mechanical Drive unit to this harness. The
location of the STU and DynamIQ is shown in
Figure 33.
4.
In-cab harness (DynamIQ ISO): runs from the
STU SmarTrax MD Harness into the cab and is
wrapped in a braided sleeve casing. It branches
off to the DynamIQ ISO.
5.
Terminal harness: runs from the the In-Cab
harness (DynamIQ ISO) to the terminal. The
terminal harness is connected with two
connectors to the in-cab harness (DynamIQ
ISO). When using a Raven 600S GPS receiver,
the 600S harness is connected to the terminal
harness too (see Figure 50).
Figure 48 and Figure 49 of the annexes show the
schematic drawings of both the CAN basic harness and
the CAN Implement harness.
FIGURE 3 RELAYS AND FUSES OF THE POWER
HARNESS.