The following offers recommended initial settings for OEM manufacturer.
NOTE:
These settings are only intended to assist with initial set up of the machine and test weight
calibrations should be performed to validate and tune these settings.]
TABLE 1.
OEM Machine Settings
Artex
Arts Way
Kuhn
SB
SBX
CB
Truck
Mounted
X700
X900
PXL1100
Fan/Spinner RPM
1
1
1
RPM 1 Cal
1
1
1
RPM Low Limit
400
800
800
RPM High Limit
2000
1200
1500
Coil Frequency (Hz)
100
100
100
PWM High Limit (%)
100
100
100
PWM Low Limit (%)
20
20
20
PWM Start Up %
25
25
25
Pulses/Revolution
200
942
2180
Spreader Constant
6
5.1
4.4
Box
Dependent
29.6
26.3
34.8
Gate Height (Max.)
48 in. [121.9 cm]
51 in.
[129.5 cm]
53 in.
[134.6 cm]
70 in.
[177.8 cm]
TABLE 2.
Scale Settings
Artex
Arts
Way
Kuhn
4 Pt
5 Pt
6 Pt
8 Pt
5 Pt
-
Cal Value
36904
46130
55356
73808
80000