The Tally Registers screen displays the following for each product node or control channel:
•
Total Volume (Ttl Vol)
•
Field Volume (Fld Vol)
•
Tank Volume (Tnk Vol)
•
Total Area (Ttl Area)
•
Field Area (Fld Area)
This screen also displays the overall distance traveled by the vehicle as calculated by the Viper Pro using the
speed sensor and programmed speed cal.
Touch the
Next
button on the Tally Registers screen to view the Odometer screen. Continue touching the
Next
button to view the Tally Registers for each product control node in the Viper Pro CANbus system.
Resetting the Tally Registers
Selecting the
Reset
button for any group of totals on the Tally Registers screen will reset the selected tally for
all nodes at the same time.
For example, touching the reset button above the field volume tally with three product nodes in the system, the
field volume for all three nodes will be reset to zero. Touch the tank volume reset button to reset the tank or bin
volumes to the preset volume value.
Note:
Review the Feature Settings Area for Granular Products section on page 144, the Feature
Settings Area for Liquid Products section on page 147 or the following Setting or Resetting
Distance and Individual Nodes section for information on setting the tank volume.
Содержание OmniSeed Viper Pro
Страница 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Страница 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Страница 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Страница 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Страница 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Страница 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Страница 250: ...Appendix A 238 OmniSeed Viper Pro Installation Operation Manual FIGURE 1 OmniSeed System Diagram 3 Bin D N 054 5010 003 ...
Страница 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Страница 255: ...Manual No 016 3001 015 Rev C 243 FIGURE 6 Seed Blockage Sensor Cabling More than 60 Sensors D N 054 5002 002 ...
Страница 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Страница 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Страница 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Страница 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Страница 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Страница 307: ......