Manual No. 016-3001-015 Rev. C
147
Advanced Settings and Features
7
Display Smoothing.
Enable the display smoothing feature to allow the field computer to smooth the rate
displayed during product applications. With this feature enabled, the actual rate (R
A
) in the rates area will
display the target rate (R
T
) as long as the actual monitored application rate remains within ±10% of the target
rate. The actual rate shown on the main screen will display the actual monitored rate if the application system
does not reach the target rate dead band (±10%) within 10 seconds.
Disable the display smoothing feature to monitor the actual application rate at all times.
Note:
The display smoothing feature is only active for products in Automatic control mode.
Feature Settings Area for Liquid Products
The information displayed in the Feature Settings area is an overview of the alarm and feature settings for the
selected product control node. For liquid products, the following settings will be displayed in the Feature
Settings area:
Note:
The following sections offer descriptions of the various options and settings used with liquid
products. For descriptions of the settings used with granular products, see the Feature Settings
Area for Granular Products section on page 144.
If the OmniSeed system will be used with a Raven AccuFlow™ system, the anhydrous system
must be assigned to product channel 4 on the Viper Pro to ensure valve shut off is performed
correctly using the switch box inputs.
•
Dual Flow %/FER Cal
•
Vacuum/Bin Alarm
•
Low PSI Alarm
•
Off Rate %
•
Decimal Shift
•
Max PSI Alarm
•
Low Tank
•
Zero Speed Shutoff
•
Standby Pressure
Enable
•
Low Limit
•
Display Smoothing
•
Dual Loop Control
•
Flow/Shaft Alarm
•
Agitator
•
Smart Control
•
Ratio Rate
Содержание OmniSeed Viper Pro
Страница 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Страница 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Страница 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Страница 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Страница 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Страница 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Страница 250: ...Appendix A 238 OmniSeed Viper Pro Installation Operation Manual FIGURE 1 OmniSeed System Diagram 3 Bin D N 054 5010 003 ...
Страница 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Страница 255: ...Manual No 016 3001 015 Rev C 243 FIGURE 6 Seed Blockage Sensor Cabling More than 60 Sensors D N 054 5002 002 ...
Страница 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Страница 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Страница 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Страница 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Страница 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Страница 307: ......