Chapter 5
116
OmniSeed™ Viper Pro™ Installation & Operation Manual
Setting or Resetting Distance and Individual Nodes
To reset an individual node, or the Viper Pro odometer from the main screen:
1.
Touch the
Product Control
area at the bottom of the main screen.
2.
Touch the
Tally Registers
button at the bottom of the CAN Controller Status screen.
3.
Touch the
Next
button on the Tally Registers screen to display the Viper Pro Odometer screen.
4.
Using the on-screen keyboard, enter the desired distance values in the appropriate fields. Touch the
Set
button to save the entered values. To reset the Odometer, touch the
Reset
button. The Viper Pro odometer
is reset to zero.
5.
Touch
Next
. The Node 1 screen displays.
6.
To set tally data for any of the displayed totals:
a.
Touch the desired field to modify.
b.
Enter the desired value and touch the
Set
button next to the entered value.
7.
To reset the data in the fields, touch the
Reset
button to the right of the value to reset.
8.
Repeat step 6 or step 7 for each node.
9.
Touch
OK
. Viper Pro saves the changes.
Note:
Field volume, field area, and tank volume can be reset while in a job. Total volume and total area
can only be reset while a job is not in progress.
Содержание OmniSeed Viper Pro
Страница 1: ...Viper Pro Software Version 3 10 OmniSeed Calibration Operation Manual ...
Страница 10: ...Table of Contents viii OmniSeed Viper Pro Calibration Operation Manual ...
Страница 98: ...Chapter 4 86 OmniSeed Viper Pro Installation Operation Manual ...
Страница 150: ...Chapter 6 138 OmniSeed Viper Pro Installation Operation Manual ...
Страница 222: ...Chapter 10 210 OmniSeed Viper Pro Installation Operation Manual ...
Страница 240: ...Chapter 11 228 OmniSeed Viper Pro Installation Operation Manual ...
Страница 250: ...Appendix A 238 OmniSeed Viper Pro Installation Operation Manual FIGURE 1 OmniSeed System Diagram 3 Bin D N 054 5010 003 ...
Страница 251: ...Manual No 016 3001 015 Rev C 239 FIGURE 2 OmniSeed System Diagram 3 Bin D N 054 3001 026 ...
Страница 255: ...Manual No 016 3001 015 Rev C 243 FIGURE 6 Seed Blockage Sensor Cabling More than 60 Sensors D N 054 5002 002 ...
Страница 256: ...Appendix A 244 OmniSeed Viper Pro Installation Operation Manual ...
Страница 284: ...Appendix D 272 OmniSeed Viper Pro Installation Operation Manual ...
Страница 292: ...Appendix G 280 OmniSeed Viper Pro Installation Operation Manual ...
Страница 300: ...Appendix H 288 OmniSeed Viper Pro Installation Operation Manual ...
Страница 304: ...Index 292 OmniSeed Viper Pro Calibration Operation Manual ...
Страница 307: ......