IMPORTANT SAFETY INFORMATION

Allow sufficient clearance from machine component operational zones such as:
• Drive shafts, universal joints and hitches (i.e. 3-point hitch)
• Pulleys, gears, sprockets
• Deflection and backlash of belts and chains
• Adjustment zones of adjustable brackets
• Changes of position in steering and suspension systems
• Moving linkages, cylinders, articulation joints, attachments
• Ground engaging components

For harness sections that move during machine operation:
• Allow sufficient length for free movement without interference to prevent: pulling, pinching, catching or 

rubbing, especially in articulation and pivot points

• Clamp harnesses securely to force controlled movement to occur in the desired harness section
• Avoid sharp twisting or flexing of harnesses in short distances
• Connectors and splices should not be located in harness sections that move

Protect harnesses from:
• Foreign objects such as rocks that may fall or be thrown by the unit
• Buildup of dirt, mud, snow, ice, submersion in water and oil
• Tree limbs, brush and debris
• Damage where service personnel or operators might step or use as a grab bar
• Damage when passing through metal structures

IMPORTANT:

Avoid directly spraying electrical components and connections with high pressure water. High pressure water 

sprays can penetrate seals and cause electrical components to corrode or otherwise become damaged. 

When performing maintenance:

Inspect all electrical components and connections for damage or corrosion. Repair or replace 

components, connections, or cable as necessary. 

Ensure connections are clean, dry, and not damaged. Repair or replace components, connections, 

or cable as necessary. 

Clean components or connections using low pressure water, pressurized air, or an aerosol electrical 

component cleaning agent. 

Remove visible surface water from components, connections, or seals using pressurized air or an 

aerosol electrical component cleaning agent. allow components to dry completely before 

reconnecting cables.

INSTRUCTIONS FOR HOSE ROUTING

The word “hose” is used to mean all flexible fluid carrying components. Follow existing hoses as much as possible 

and use these guidelines:

Hoses should not contact or be attached to:
• Components with high vibration forces
• Components carrying hot fluids beyond component specifications

Avoid contact with any sharp edge or abrading surfaces such as, but not limited to:

Содержание Hagie Hawkeye STS

Страница 1: ...Hagie Hawkeye Installation Manual P N 016 0171 635 Rev C 05 17 E29489 Copyright 2017 ...

Страница 2: ...er s responsibility The Return Materials Authorization RMA number must appear on the box and all documentation including proof of purchase must be included inside the box to be sent to Raven Industries WHAT WILL RAVEN INDUSTRIES DO Upon confirmation of the warranty claim Raven Industries will at our discretion repair or replace the defective product and pay for the standard return freight regardle...

Страница 3: ...ral Valve Installation 16 Boom Cable Routing and Connection 16 Best Practices and Recommendations 16 Secondary Boom Cable Routing and Connections 17 Primary Boom Cable Routing and Connections 17 Chapter 6 Cab Preparation and Wiring 19 Console Cable Routing and Connection 19 Best Practices and Recommendations 19 Viper 4 and Console Cable Connections 19 SmarTrax Node Cable Installation 23 Norac Adap...

Страница 4: ...er Cable Installation 28 ISO Interface Cable Installation 30 Center Rack Cable Harness Installation 34 Appendix A System Diagram 37 Chapter B Cable and Connector Maintenance 41 Power and ECU Harness Maintenance 41 Hawkeye Boom Harness Connector Maintenance 41 ...

Страница 5: ... Do not drive the machine with equipment enabled on any public road Determine and retain a safe working distance from other individuals The operator is responsible for disabling Hawkeye when the safe working distance has been diminished Ensure Hawkeye is disabled prior to starting any maintenance work on the system or the implement AGRICULTURAL CHEMICAL SAFETY Thoroughly bleed pressure from chemic...

Страница 6: ...ss is used to mean all electrical leads and cables bundled and unbundled When installing harness secure it at least every 30 cm 12in to the frame Follow existing harness as much as possible and use these guidelines Harness should not contact or be attached to Lines and hoses with high vibration forces or pressure spikes Lines and hoses carrying hot fluids beyond harness component specifications Av...

Страница 7: ... operators might step or use as a grab bar Damage when passing through metal structures IMPORTANT Avoid directly spraying electrical components and connections with high pressure water High pressure water sprays can penetrate seals and cause electrical components to corrode or otherwise become damaged When performing maintenance Inspect all electrical components and connections for damage or corro...

Страница 8: ...hitches i e 3 point hitch Pulleys gears sprockets Deflection and backlash of belts and chains Adjustment zones of adjustable brackets Changes of position in steering and suspension systems Moving linkages cylinders articulation joints attachments Ground engaging components For hose sections that move during machine operation Allow sufficient length for free movement without interference to prevent...

Страница 9: ...llers on the market This manual is intended to provide installation instructions on the following equipment TABLE 1 Make and Model Information REQUIRED COMPONENTS The following components must be installed with the Hawkeye nozzle control system Updated software on field computers or control monitors PWM pump control valve Make Model Model Year Boom Configuration Hagie STS 2014 2015 90 Boom 15 Spac...

Страница 10: ...IT CONTENTS TABLE 2 Hagie STS 2014 2015 90 Boom 15 Spacing Kit P N 117 1007 043 Hagie STS 2016 2017 90 Boom 15 Spacing Kit P N 117 1007 044 Hagie STS 2014 2015 100 Boom 15 Spacing Kit P N 117 1007 045 Hagie STS 2016 2017 100 Boom 15 Spacing Kit P N 117 1007 046 Hagie STS 2014 2015 120 Boom 15 Spacing Kit P N 117 1007 040 Hagie STS 2016 2017 120 Boom 15 Spacing Kit P N 117 1007 041 Picture Item Des...

Страница 11: ...Product Control II Hagie 115 7303 167 1 Cable Center Rack Harness Hawkeye Hagie STS 2014 115 7303 327 1 Cable ECU Extension Port B Hawkeye 115 7303 319 1 Cable Secondary Hagie STS 90 Boom 15 Spacing 115 7303 347 2 Cable Secondary Hagie STS 100 Boom 15 Spacing 115 7303 348 2 Cable Secondary Hagie STS 120 Boom 15 Spacing 115 7303 097 2 Picture Item Description Part Number Qty 117 1007 043 044 045 04...

Страница 12: ... Transducer Extension Hagie STS 2014 2015 115 0171 448 1 1 1 Cable Resistor Pressure Transducer Hagie STS 2014 2015 115 7303 330 1 1 1 Cable Right Primary Hagie STS 100 and 90 Boom 15 Spacing 115 7303 345 1 Cable Left Primary Hagie STS 100 and 90 Boom 15 Spacing 115 7303 345 1 Cable Right Primary Hagie STS 120 Boom 15 Spacing 115 7303 095 1 Cable Left Primary Hagie STS 120 Boom 15 Spacing 115 7303...

Страница 13: ...02 319 75 83 99 Wilger Adapter Assembly Combo Jet to SS 333 0002 322 150 166 198 Wilger End Nozzle Body Blended Pulse 333 0002 325 75 83 99 Wilger Nozzle Body 1 2 Way 3 8 Modified 333 0002 332 75 83 99 Picture Item Description Part Number Qty 117 1007 043 044 045 046 040 041 ...

Страница 14: ...ing as possible One way to improve this experience is to provide us with feedback on this manual Your feedback will help shape the future of our product documentation and the overall service we provide We appreciate the opportunity to see ourselves as our customers see us and are eager to gather ideas on how we have been helping or how we can do better To serve you best please send an email with t...

Страница 15: ...isable the application control system and de pressurize the boom 6 Replace existing carrier line strainer s with an 80 mesh strainer An 80 mesh or finer strainer is required for use with the Hawkeye nozzle control system 7 Remove the existing TeeJet nozzle bodies on the boom tube and set them aside These will be replaced with Wilger nozzle bodies later 8 Ensure no persons or property are near the ...

Страница 16: ...CHAPTER 3 12 Hagie Hawkeye Installation Manual ...

Страница 17: ...the U Pin to retain the end nozzle body 5 Install the Wilger Plug onto the other end of the nozzle body squeeze together and install the U Pin to retain the plug 6 Install the Wilger Tip Adapter onto each of the two outlets of the nozzle body Rotate 1 4 turn to secure 7 Repeat the above assembly steps for each of the provided nozzle bodies Part Number Description 333 0002 331 Wilger Nozzle Body 1 ...

Страница 18: ...CHAPTER 4 14 Hagie Hawkeye Installation Manual ...

Страница 19: ...r nozzle bodies that were assembled in Wilger Nozzle Body Assembly on page 13 2 Begin installing the Wilger nozzle bodies onto the boom tube verifying the spray pattern out of each of the nozzle body outlets has a clear path to spray below the boom If there is an interference the End Nozzle Body P N 333 0002 325 and the Plug P N 333 0002 319 may need to be switched around on the Nozzle Body in ord...

Страница 20: ...he nozzle control valve nuts to ensure they are secure 5 Repeat the previous steps to mount a nozzle control valve to each nozzle body on the spray boom VALVE MOUNTING INTERFERENCE AND OBSTRUCTIONS In some locations on the spray boom boom equipment or hardware may interfere with mounting the Hawkeye nozzle control valves In these locations it may be necessary to rotate the nozzle control valve or ...

Страница 21: ...the terminators are located at the outer tips of the left and right boom 4 Starting from the mid boom fold point feed the terminator end of the secondary boom cable through the boom framework Follow the existing cable or plumbing runs and through existing cable retention devices as appropriate 5 If not already applied apply a single short burst of corrosion inhibitor Corrosion X HD Raven P N 222 0...

Страница 22: ...ient slack around the mid boom fold point and allow each cable to reach nozzle control valves near the folding point 5 Secure the boom cables using zip ties to protect the connector from damage during folding and unfolding operations 6 Connect the valve branches to the nozzle control valves starting with the valve on the primary boom segment furthest from the center of the implement 7 At each valv...

Страница 23: ...o help avoid pinch points or stretching the cable during normal equipment operation VIPER 4 AND CONSOLE CABLE CONNECTIONS 1 Start the machine and using the hydraulic controls completely extend the front right axle out to gain access to the exterior cab panel 2 Remove the exterior cab panel Refer to Figure 1 Exterior Cab Access Panel Removed FIGURE 1 Exterior Cab Access Panel Removed 3 In the cab l...

Страница 24: ... black round Christmas tree clip located directly below the A Post cover in the compartment that secures the plastic A Post cover to the compartment 5 Carefully remove the A Post cover by gently pulling towards the center of the cab Cab Access Panel Removed Black Round Plug Inside Compartment A Post Cover ...

Страница 25: ...he existing small gauge wire P N 115 0172 087 connected to all power and ground leads 10 Locate the provided Viper 4 console cable P N 115 7302 010 11 Route the three round Viper 4 connectors up the through the electrical compartment and up the A post It will exit the A post near the roof 12 Connect any serial connections light bar weather station etc used on the old console cable 13 Gently press ...

Страница 26: ...d Power Studs 18 Connect the two red positive ring terminals to the stud located in the bottom of the electrical compartment 19 Locate and connect the large round connector of the Hagie chassis cable to the large round mating connector of the console cable P N 115 7302 010 20 Locate and connect the ignition power ring terminal smaller gauge wire on the console cable P N 115 7302 010 to the ignitio...

Страница 27: ... the hardware retained in step 21 SMARTRAX NODE CABLE INSTALLATION 1 Locate the existing SmarTrax node and harness P N 115 4001 169 refer to Figure 6 on page 23 2 Disconnect the harness from the node and all other connections 3 Connect the provided SmarTrax cable harness P N 115 4001 229 to the SmarTrax node console cable and other connections from step 2 NORAC ADAPTER CABLE INSTALLATION OPTIONAL ...

Страница 28: ...CHAPTER 6 24 Hagie Hawkeye Installation Manual ...

Страница 29: ...from the machine to remove the cover 4 Using a 1 4 driver remove the two electrical connectors from the Raven Multi Product Node 5 Remove the Multi Product Node from the machine and set it aside This is not needed for the Hawkeye system 6 Follow the product control cable harness that was disconnected from the node and disconnect all control cable harness connections from the machine 7 Remove the h...

Страница 30: ...ct Control Cable This is not needed for the Hawkeye installation 8 Remove the Multi Product Node from the machine and set it aside This is not needed for the Hawkeye installation PRODUCT CONTROLLER II INSTALLATION BEST PRACTICES AND RECOMMENDATIONS Do not connect battery leads until all cables are installed and connected If a protected mounting location is not available on the equipment mount the ...

Страница 31: ... retaining clips and allow the panel to open 2 Lower the front fill assembly to gain access for cable routing 3 On the front most under body cover panel remove the retaining clips and allow the panel to open 4 Locate the ECU product control cable P N 115 7303 167 5 Connect the two 12 pins connectors on the ECU product control cable into the appropriately keyed ports on the ECU ...

Страница 32: ...e The bottom edge of the PC II ECU should be parallel with the bottom edge of the frame rail 10 Connect the 12 pin Deutsch from the ECU product control cable P N 115 7303 167 to the end of the 12 pin Deustch plug feed through the opening in the previous section 11 Route the port b extension cable over the front axle along the right hand frame rail and towards the right hand center rack linkage POW...

Страница 33: ...nd secure the power ring terminal to the power stud 7 Route the round connector of the power harness along the left hand frame rail and over the rear and front axles towards the right hand center rack linkage Ensure the harness will not get pinched when the under body cover panels are closed 8 Secure the harness with zip ties 9 Close and secure the rear most under body cover panel JOHN DEERE ENGIN...

Страница 34: ... the negative ground stud on the back side of the panel FIGURE 8 John Deere Engine Power Connections 6 Route the round connector of the power harness along the right hand frame rail over the rear and front axles towards the right hand center rack linkage Ensure the harness will not get pinched when the under body cover panels are closed 7 Secure the harness with zip ties ISO INTERFACE CABLE INSTAL...

Страница 35: ...he ISO interface cable and route them over the from axle towards the power and ground studs located on the floor of the cab just in front of the front axle 7 Connect the ground ring terminal to the ground stud FIGURE 10 Power Stud Location 8 Connect the ignition power ring terminal to the power stud located towards the right hand side of the machine from the constant power stud 9 Locate the provid...

Страница 36: ...being disconnected FIGURE 11 Pressure Transducer Connection NOTE This system uses the Hagie OEM pressure transducer This is a 0 300 psi 1 5 Volt transducer which requires custom calibration on the Hawkeye screen once installation is complete The value needed is 13 33 mV psi for this transducer See the Hawkeye Operation Manual P N 016 0171 584 for more information on Custom Transducer Calibration 1...

Страница 37: ...onnect to the mating receptacle of the ISO product control cable P N 115 7303 167 6 Connect the 12 pin Deutsch receptacle to the Hagie harness cable 7 Locate the power and ground ring terminals on the ISO interface cable and route them over the from axle towards the power and ground studs located on the floor of the cab just in front of the front axle 8 Connect the ground ring terminal to the grou...

Страница 38: ... hand side of the machine from the constant power stud CENTER RACK CABLE HARNESS INSTALLATION 1 Locate the provided center rack cable harness P N 115 7303 327 2 Locate the breakout with the 12 pin Deutsch receptacle and the large round connector 3 Install these connectors into the bulkhead bracket near the right hand linkage of the center rack Power Stud Location ...

Страница 39: ...ong the top bar of the linkage towards the center rack 7 Connect the right and left primary boom cables to the center rack harness Use the labels on the center rack harness to identify left and right boom cable connections 8 Locate the 3 pin Deutsch plug of the transducer extension cable and route this along with the center rack harness 9 Secure the cabling with zip ties while ensuring there is en...

Страница 40: ...CHAPTER 7 36 Hagie Hawkeye Installation Manual ...

Страница 41: ...APPENDIX A P N 016 0171 635 Rev C 37 APPENDIXASYSTEM DIAGRAM ...

Страница 42: ...APPENDIX A 38 Hagie Hawkeye Installation Manual ...

Страница 43: ...P N 016 0171 635 Rev C 39 ...

Страница 44: ...APPENDIX A 40 Hagie Hawkeye Installation Manual ...

Страница 45: ...to the Hawkeye Nozzle Control Valves NCV perform the following steps to all 6 pin NCV connectors and 19 pin circular connectors between the boom cables and ECU cable connections to ensure high quality connections 1 Verify the NCV connectors and the accompanying boom cable connectors are free of moisture contamination or oxidation Oxidation will appear as a dry white coating on the contacts If any ...

Страница 46: ...move all residue of deoxidizing agent from the connection Not removing deoxidizing agent can damage the connector seal 6 Dry out the connection with dry compressed air Dust Off Electronics Duster P N 222 4001 007 is recommended however if unavailable alternate compressed air sources can be used If using compressed air from a large volume air compressor be sure the lines are free of moisture ...

Страница 47: ...m corrosionx heavy duty html into the NCV connection Be sure the corrosion inhibitor has coated the NCV contacts and recessed portions of the connector NOTE To determine is corrosion inhibitor has been applied inspect for a thick liquid in the bottom of the connector as shown in the Corrosion Inhibitor Applied image below NCV Connector Applying Corrosion Inhibitor Spray in Void Between Pins Corros...

Страница 48: ...APPENDIX B 44 Hagie Hawkeye Installation Manual ...

Страница 49: ... 016 4001 150 Rev A 45 B Boom Cable 16 17 C Chemical Safety 1 Console Cable 19 Cummins 28 E ECU 25 ECU Harness 27 Electrical Safety 2 J John Deere 29 P Product Controller 26 V Valve Installation 16 Viper 4 19 21 ...

Страница 50: ...Index 46 Kubota M7 Series SmarTrax Installation Manual ...

Страница 51: ... claim and send it to Raven Industries for final approval The freight cost to Raven Industries will be the customer s responsibility The Return Materials Authorization RMA number must appear on the box and all documentation including proof of purchase must be included inside the box to be sent to Raven Industries In addition the words Extended Warranty must appear on the box and all documentation ...

Страница 52: ...aven Industries shall not be held responsible for any modifications or repairs made outside our facilities nor damages resulting from inadequate maintenance of this system As with all wireless and satellite signals several factors may affect the availability and accuracy of wireless and satellite navigation and correction services e g GPS GNSS SBAS etc Therefore Raven Industries cannot guarantee t...

Отзывы: