CHAPTER 4
32
Hawkeye® 2 Installation Manual for AGCO RoGator C-Series (RG900, RG1100, RG1300)
BOOM CABLE ROUTING AND CONNECTIONS (INNER, MIDDLE, AND OUTER BOOM CABLES)
1. Locate the boom cables included with the Hawkeye® 2 installation kit. There are typically six boom cables for a
single system:
•
2 inner boom cables (may be left and right specific).
•
2 mid boom cables.
•
2 outer boom cables.
2. On the inner boom cable, locate the end of the cable with the rotating locking collar.
3. Start with the rotating locking collar side of the cable near the center of the center rack and route the cable
going outwards towards the boom tip, following plumbing routing whenever possible.
NOTE:
Keep the boom connections clean and off the ground while routing.
Do not secure cables with cable ties until all cables are in place and routings are checked for pinch
points and other interferences.
Ensure sufficient slack is available at fold and break-away joints to allow for full range of motion
without stretching the cable.
4. Next, repeat step 1 through 3 for the inner boom cable for the opposite side.
5. Continue routing both mid and outer boom cables, and repeat step 1 through 4 for both mid and outer boom
cables.
NOTE:
The connector with the rotating locking collar will always go towards the center of the machine.
6. If not already applied, apply a single, short burst of corrosion inhibitor. Corrosion X HD (P/N 222-0000-020 or
available from http://www.corrosionx.com/corrosionx-heavy-duty.html) is recommended.
7. Be sure the corrosion inhibitor has coated the NCV contacts and recessed portions of the connector.
NOTE:
To determine if corrosion inhibitor has been applied, inspect for a thick liquid in the bottom of the
connector.
8. Once all boom cables are routed along the boom as desired, begin connecting the boom cables to the
Hawkeye® 2 NCVs previously installed.
9. Use provided cable ties to secure the boom cables to the boom components as needed to ensure they are
secure.
NOTE:
Do not put strain on cables and connections while applying tie-downs.
Do not leave any exposed cable loops that may get caught on crops or other debris while the vehicle
is in use.
10. The inner boom cables will be connected to the ECU cable in a later section.
Содержание AGCO RoGator Hawkeye C Series
Страница 8: ...CHAPTER 1 4 Hawkeye 2 Installation Manual for AGCO RoGator C Series RG900 RG1100 RG1300...
Страница 24: ...CHAPTER 2 20 Hawkeye 2 Installation Manual for AGCO RoGator C Series RG900 RG1100 RG1300...
Страница 26: ...CHAPTER 3 22 Hawkeye 2 Installation Manual for AGCO RoGator C Series RG900 RG1100 RG1300...
Страница 52: ...CHAPTER 6 48 Hawkeye 2 Installation Manual for AGCO RoGator C Series RG900 RG1100 RG1300...
Страница 56: ...CHAPTER 7 52 Hawkeye 2 Installation Manual for AGCO RoGator C Series RG900 RG1100 RG1300...
Страница 60: ...APPENDIX A 56 Hawkeye 2 Installation Manual for AGCO RoGator C Series RG900 RG1100 RG1300...
Страница 62: ......