Use and maintenance manual
Vela 11
Rev.1 09.02.18
EN
Pag.70
Position of the switch,
protected by the screw cap, for
the safety reset thermostat on
the back of the stove.
AL 04
FUME EXHAUST
DAMAGED
Fume exhaust encoder is not working or is
connected incorrectly
Contact the Support Service
No power to fume extractor.
Contact the Support Service
The fume extractor is blocked.
Contact the Support Service
AL 05 NO SWITCH-ON
The pellet tank is empty.
Check for the presence of pellets in the
container.
Top up, if necessary.
Pellet calibration and suction during switch on
phase is incorrect.
Contact the Support Service
The ignition coil is faulty or positioned
incorrectly
Contact the Support Service
AL 06
PELLETS
FINISHED
The pellet tank is empty.
Check for the presence of pellets in the
container.
Top up, if necessary.
The gear motor is not loading pellets.
Empty the tank to see if there are any objects
inside that may prevent proper operation of the
auger.
Not enough pellets loaded
Regulate pellets setting from “SET AIR/
PELLETS”
If the problem persists, contact the Support
Service
AL 07
RESETTABLE
THERMAL
BREAKER
- The manual reset thermostat has tripped
connected to the hopper (RESET THERMAL
BREAKER / Pellet door or gate is open
- Reset the thermostat by pressing the button on
the back of the stove or close the doors.
- Combustion in the grate is not optimal
due to the fact that the grate is clogged or
the inner stove ducts are clogged. (RESET
THERMAL BREAKER)
Switch off the stove, clean the brazier and the
tube bundle and adjust the combustion setting
the Pellet/Air values
Contacter le Service d’Assistance
AL 08
DEPRESSURIZATION
The flue is blocked.
Check the flue is free and clean
The vacuum meter is faulty.
Check the mains voltage.
AL 12
FUME EXHAUST
SYSTEM
The fume exhaust system has a loss of
performance due to fan obstruction or voltage
drop.
Check the mains voltage.
AL 14
SCREW PHASE
No cable connection to power the gear motor
screw
Check the mains voltage.
AL 15 SCREW TRIAC
An internal part of the electronic board that
controls the pellet infeed screw is faulty.
Check the flue is free and clean
Possible voltage drops or incorrect input
voltage stove inlet
Check the mains voltage.
AL 19
CLEANER FAILURE
(for models
equipped with
cleaner)
The cleaner did not complete the movement
and is not in the correct position
Reset the alarm and wait for the stove to switch
to SHUTDOWN mode. Cut off and power again,
the system reactivates the cleaner searching the
correct position again.
If the problem persists, contact the Support
Service
Содержание VELA 11
Страница 2: ......
Страница 42: ...DATA INTERVENTO EFFETTUATO MANUTENZIONE ...
Страница 76: ...DATE WORK PERFORMED MAINTENANCE ...
Страница 110: ...DATE INTERVENTION EFFECTUÉE ENTRETIEN ...
Страница 181: ...DATE WORK PERFORMED MAINTENANCE ...
Страница 182: ...DATE WORK PERFORMED MAINTENANCE ...
Страница 183: ......