Use and maintenance manual
Infinity Plus 7-9
Rev.1 26/03/2018
EN
Pag.62
Feed screw loading
Before starting the stove for the first time, whenever the stove is in alarm “06 - Pellets finished”, and in any case whenever the hopper
has emptied completely, the initial feed screw loading is required. This phase involves filling the pellet loading system so that when
the system is started, it is ready to load the pellets into the brazier.
In the event that the feed screw operations are not carried out, there may be stove ignition failures.
THE PRE-SET INITIAL LOADING TIME IS SUCH TO ALSO INCLUDE ENOUGH PELLETS FOR THE FIRST IGNITION.
AFTER THE INITIAL LOADING OPERATIONS, NO BRAZIER CLEANING WILL PRECEDE THE IGNITION PHASE.
Setting operating temperature and power:
Set the two values following the indications given in the chapter “Description of thr display”
Turning the device on
Keep the key ON/OFF pressed for a few seconds to turn on the stove.
User’s manual HANDHELD TOUCH RADIO
User’s manual HANDHELD TOUCH RADIO
Pag.22
Pag.23
Vers. 01 of:07.04.14
Vers. 01 of:07.04.14
Loading the auger
MENU
USER
SCREW FEEDING
SCREW FEEDING
CHRONOTHERMOSTAT
AIR-PELLET SET
STOVE STATE
USER
MANUFACTURER
ENGINEER
MENU
USER
MANUFACTURER
ENGINEER
USER
USER
COMFORT CLIMA
COMFORT CLIMA
COMFORT CLIMA
COMFORT CLIMA
ENABLE COMFORT
ENABLE COMFORT
ENABLE COMFORT
RESTART DELTA
RESTART DELTA
SHUTDOWN DELAY
SHUTDOWN DELAY
SHUTDOWN DELAY
SHUTDOWN DELAY
ENABLE COMFORT
ENABLE COMFORT
COMFORT CLIMA DELTA
COMFORT CLIMA DELTA
RESTART DELTA
SHUTDOWN DELAY
SETTINGS
SCREW FEEDING
CHRONOTHERMOSTAT
AIR-PELLET SET
STOVE STATE
ALWAYS EMPTY THE BRAZIER BEFORE TURNING THE STOVE ON AND ALWAYS CHECK
THAT ALL NONE OF ITS HOLES IS CLOGGED NEVER EMPTY THE RBAZIER INSIDE THE HOPPER.
FIRE HAZARD.
Carry out this operation to facilitate stove’s first start operations; You should also check that you have introduced pellets
into the hopper and wait until the stove is in “SHUTDOWN” or “FINAL CLEANING” mode. The number expressed in sec-
onds indicates the rotation time of the infeed screw during the first loading cycle. Once this time has elapsed, the infeed
screw stops immediately and then pellets are emptied from the grate before turning on the equipment.
Below are given the steps for accessing the relative menu.
Press the key “access
menu” to access
the
MENU page
Press the key
“confirm”
to access the
USER page
At the end of the auger loading, the display shows 0 “and automatically switches to the USER menu page.
Press the key for several times until the Stand-by page is displayed.
Setting operating temperature and power:
Set the two values following the indications given in the chapter “Description of thr display”
Turning the device on
Keep the key ON/OFF pressed for a few seconds to turn on the stove.
Press CONFIRM to enable
the rotation of the auger
The appearance of the message “ADJUST THE RDS SYSTEM” indicates that the initial parameter testing procedure
and calibration has been unsuccessfully. This indication does not cause stove blockage (see the SIGNALLING POP UP
section).
On the display of the handheld set appears the following:
Press and hold the ON/OFF button to turn off the stove door, and reset any alarms triggered.
In case the infeed screw operations described avobe have not been executed, the stove may fail to turn on. In this case,
carry out the operations described above and empty the brazier and reset the alarm.
If the stove still fails to turn on, check that the grate is properly installed and perfectly adherent to the base, and also check that
there are no deposits that prevent the smooth passage of air to enable ignition. If the problem persists, contact the support ser
-
vice.
Sequence of ignition phases
SWITCH-ON- initial pellet loading phase;
WAIT FLAME - flame
development wait
phase;
FLAME PRESENT - flame stabilization
phase and reduction of combustible
inside the brazier;
What happens if the batteries are empty?
If the battery is discharged, within the
“drop” is shown a symbol that indicates
that the battery is empty, while maintain-
ing active the features of your device.
WORK - operation phase
described in
the dedicated chapter;
As soon as the level of the battery
prevents the radio communication the
handheld set displays on full screen the
picture of empty battery and all device
functions are locked until the batteries
are replaced
CONNECT AN EXTERNAL THERMOSTAT WITH A SIMPLE DRY CONTACT, THEREFORE, NOT POWERED. MORE-
OVER, WE RECOMMEND YOU USE A THERMOSTAT WITH A MINIMUM OFFSET OF 3°C IF YOU INTEND TO USE
THE COMFORT CLIMA FUNCTION.
Operating phases of the appliance
Modulation
During the work phase, the appliance should reach the room temperature set; when this condition is met, the stove switches to
MODULATION mode in which fuel consumption and ventilation are minimum.
If you wish to detect the ambient temperature by means of an external thermostat (optional), this must be connected to
the appropriate connector on the rear side of the stove; and you will have to activate the reading in “SETTINGS - EN -
ABLE THERMOSTAT.” On display appears the writing TON / TOFF based on thermostat request.
Comfort climate
The activation of this function enables the stove to reduce pellet consumption by activating the modulation phases, after the desired
temperature has been reached. Subsequently, the stove checks that the temperature is maintained steady for a preset time. If this
condition is met, it automatically switches off, and on display appears the writing ECO.
The stove turns on again when the temperature drops below the set threshold.
Below are given the steps for accessing the relative menu.
Press the key
“access menu” to
access
the
MENU page
Press the key
“confirm”
to access the
USER page
Once you have accessed the Climate Comfort menu, it is possible to operate on the 3 types of settings dedicated to the function:
Press the key for several times until the Stand-by page is displayed.
Press the key “selection” for
“selection”
to switch to the second page
of USER MENU and select
CLIMATE COMFORT.
Manuale utente PALMARE IDRO TOUCH RADIO
Manuale utente PALMARE IDRO TOUCH RADIO
Pag.26
Pag.27
Vers. 01 del 07/04/15
Vers. 01 del 07/04/15
Phases de fonctionnement de l’appareil
Pendant la phase de travail, le but de l’appareil est celui d’atteindre le réglage de la température ambiante/eau chaudière demandée
par l’utilisateur, quand cette condition est remplie, le poêle passe en modalité MODULE, phase pendant laquelle la consommation
de combustible est minimum.
La modulation
Au cas où l’on voudrait relever la temperature ambiante au moyen d’un thermostat externe (option), celui-ci devra être
raccordé au connecteur spécialement placé sur la partie arrière du poêle; on devra par consequent activer la lecture
Dans le menu spécial “CONFIGURATIONS – HABILITATION THERMOSTAT”. Sur l’afficheur apparaitra l’inscription TON
/ TOFF sur la base de la demande du thermostat.
RACCORDER UN THERMOSTAT EXTERNE QUI AIT SIMPLEMENT UN CONTACT PROPRE, PAR CONSEQUENT
NON EN TENSION. EN OUTRE UN THERMOSTAT EST CONSEILLE AVEC OFFSET D’AU MOINS 3°C SI ON VEUT
UTILISER LA FONCTION CONFORT CLIMA.
L’activation de cette fonction permet au poêle, une fois atteinte la température ambiante/eau chaudière voulue, de réduire le
chargement de pellet en activant la phase de modulation. Successivement le poêle vérifie que la température soit maintenue pendant
une période de temps établi, et si cela se produit, il passe automatiquement en extinction, en montrant sur l’afficheur l’inscription
ECO.Le poêle se rallume quand la température descend en-dessous d’un seuil configuré.
Ci-après sont reportées les opérations à suivre pour accéder au menu relatif.
Confort clima
Pression de la touche de
“accès au menu” pour
accéder à la
page-écran MENU
Pression de la touche
“confirmation”
pour accéder à la
page-écran UTILISATEUR
Pression de la touche de
“sélection”
pour passer à la seconde
page-écran de menu UTILISATEUR
et sélectionner
CONFORT CLIMA.
Une fois effectué l’accès au menu Confort clima il est possible d’opérer sur les 4 types de configurations dédiées à la fonction :
Appuyer à plusieurs reprises la touche jusqu’au retour de l’écran de Stand-by.
R
églage de la température ambiante et eau chaudière:
Configurer les deux valeurs en suivant les indications fournies dans le chapitre “Description du display”
Allumage de l’appareil
Maintenir la pression sur la touche ON/OFF pendant quelques secondes pour allumer le poêle.
L’afficheur illustrera la page-écran suivante :
Une pression prolongée de la touche ON/OFF provoque l’extinction du poêle, ansi que le reset d’éventuelles alarmes. Dans le cas
où les opérations de chargement de la vis d’Archimède décrites ci-avant n’aient pas été exécutées, cela pourrait donner lieu à des
épisodes de non allumage du poêle. Vider le brasier et remettre à zero l’alarme et répéter l’allumage. Au cas où se produiraient des
non-allumages répétés, contrôler que le brasier soit logé et en parfait contact avec la base d’appuii; Verifier en outre que ne soient
pas présentes d’inscrustations qui empêchent le passage correct d’air pour permettre l’allumage.
Si le problème persiste, contacter le service d’assistance.
Modification de la puissance du poêle
L’apparition du message “REGLER SYSTEME RDS” indique que la procédure d’essai et réglage des paramètres Initial
n’est pas effectuée correctement. Cette indication n’implique pas le blocage du poêle (voir section POP UP D’INDICATION).
Séquence des phases d’allumage
ALLUMAGE – phase initiale de
chargement pellet;
ATTENTE FLAMME – phase d’attente
développement de la flame ;
PHASE FLAMME – phase de
stabilisation flamme et réduction
comburant à l’intérieur du brasier
TRAVAIL – phase de fonctionnement
Décrite dans le chapitre dédié;
En case de batterie déchargée à
l’intérieur de la “goutte” est présent un
symbole Qui indique l’état de limite de
celle-ci, tout en maintentant actives les
fonctions de l’ordinateur de poche.
Dès que le niveau de batterie ne permet
en aucune sorte la communication radio,
l’ordinateur de poche affiche plein écran
entier l’image de la batterie déchargée,
en bloquant toute les fonctions de
l’ordinateur portable jusqu’à l’effective
substitution des batteries.
Que se passe-t-il en cas de batteries déchargées
Pour les modèles avec nettoyeur automatique, pendant la phase d’allumage, le poêle active une phase de nettoyage du
brasier avant de passer à l’ALLUMAGE. En cas de NON ALLUMAGE il n’est pas nécessaire d’enlever le pellet non brûlé
À l’intérieur du brasier avant d’effectuer un nouvel allumage. Dès que l’utilisateur rallume le poêle, le système de
fonctionnement exécute l’opération sans activer le nettoyeur et sans démarrer à nouveau la phase de chargement.
Pression de la touche d’
“accès au menu” pour
accéder à la
page-écran MENU
Pression de la touche
“confirmation”
pour accéder à la
page-écran UTILISATEUR
Pression de la touche
“confirmation”
pour accéder à la
page-écran SELECTION
PUISSANCE :
A l’aide des touches “EN HAUT” et “EN BAS” il est
possible de modifier la puissance de travail.
La pression de la touche suivante permet la confirmation
de la donnée et du retour au MENU UTILISATEUR
La sélection de la puissance est effective uniquement en phase de travail du poêle. A chaque allumage celle-ci assume toujours
la puissance maximum afin de garantir le plus grand apport de chaleur à l’installation de chauffage
Sélectionner le type de gestion
Confort Clima sur la t°C
Eau ou sur la température
ambiante au moyen de la touche
flèche EN HAUT ou flèche EN
BAS
Touche “V” pour confirmer la
“sélection”
MENU
BATTERIE BASSE
BATTERIE BASSE
UTILISATEUR
TECHNIQUE
PRODUCTEUR
UTILISATEUR
REGLAGE PUISSANCE
SELECTION PUISSANCE
CHRONOTHERMOSTAT
CHARGEMENT VIS D’ARCHIMEDE
SET AIR-PELETT
MENU
UTILISATEUR
TECHNIQUE
PRODUCTEUR
UTILISATEUR
UTILISATEUR
REGLAGE PUISSANCE
ETAT POELE
CHRONOTHERMOSTAT
CONFORT CLIMA.
CONFORT CLIMA.
CONFORT CLIMA.
AIR
EAU
DELTA CONFORT
CLIMA
DELTA CONFORT
CLIMA
RETARD
EXTINCTION
RETARD
EXTINCTION
CONFORT CLIMA.
CONFORT CLIMA.
CHARGEMENT VIS D’ARCHIMEDE
CONFIGURATIONS
SET AIR-PELETT
ACTIVATION CONFORT
ACTIVATION CONFORT
ACTIVATION CONFORT
ACTIVATION CONFORT
ACTIVATION CONFORT
ACTIVATION CONFORT
GESTION CONFORT
GESTION CONFORT
GESTION CONFORT
GESTION CONFORT
DELTA REDEMARRAGE
DELTA REDEMARRAGE
DELTA REDEMARRAGE
DELTA REDEMARRAGE
RETARD EXTINCTION
RETARD EXTINCTION
RETARD EXTINCTION
RETARD EXTINCTION
Manuale utente PALMARE IDRO TOUCH RADIO
Manuale utente PALMARE IDRO TOUCH RADIO
Pag.26
Pag.27
Vers. 01 del 07/04/15
Vers. 01 del 07/04/15
Phases de fonctionnement de l’appareil
Pendant la phase de travail, le but de l’appareil est celui d’atteindre le réglage de la température ambiante/eau chaudière demandée
par l’utilisateur, quand cette condition est remplie, le poêle passe en modalité MODULE, phase pendant laquelle la consommation
de combustible est minimum.
La modulation
Au cas où l’on voudrait relever la temperature ambiante au moyen d’un thermostat externe (option), celui-ci devra être
raccordé au connecteur spécialement placé sur la partie arrière du poêle; on devra par consequent activer la lecture
Dans le menu spécial “CONFIGURATIONS – HABILITATION THERMOSTAT”. Sur l’afficheur apparaitra l’inscription TON
/ TOFF sur la base de la demande du thermostat.
RACCORDER UN THERMOSTAT EXTERNE QUI AIT SIMPLEMENT UN CONTACT PROPRE, PAR CONSEQUENT
NON EN TENSION. EN OUTRE UN THERMOSTAT EST CONSEILLE AVEC OFFSET D’AU MOINS 3°C SI ON VEUT
UTILISER LA FONCTION CONFORT CLIMA.
L’activation de cette fonction permet au poêle, une fois atteinte la température ambiante/eau chaudière voulue, de réduire le
chargement de pellet en activant la phase de modulation. Successivement le poêle vérifie que la température soit maintenue pendant
une période de temps établi, et si cela se produit, il passe automatiquement en extinction, en montrant sur l’afficheur l’inscription
ECO.Le poêle se rallume quand la température descend en-dessous d’un seuil configuré.
Ci-après sont reportées les opérations à suivre pour accéder au menu relatif.
Confort clima
Pression de la touche de
“accès au menu” pour
accéder à la
page-écran MENU
Pression de la touche
“confirmation”
pour accéder à la
page-écran UTILISATEUR
Pression de la touche de
“sélection”
pour passer à la seconde
page-écran de menu UTILISATEUR
et sélectionner
CONFORT CLIMA.
Une fois effectué l’accès au menu Confort clima il est possible d’opérer sur les 4 types de configurations dédiées à la fonction :
Appuyer à plusieurs reprises la touche jusqu’au retour de l’écran de Stand-by.
R
églage de la température ambiante et eau chaudière:
Configurer les deux valeurs en suivant les indications fournies dans le chapitre “Description du display”
Allumage de l’appareil
Maintenir la pression sur la touche ON/OFF pendant quelques secondes pour allumer le poêle.
L’afficheur illustrera la page-écran suivante :
Une pression prolongée de la touche ON/OFF provoque l’extinction du poêle, ansi que le reset d’éventuelles alarmes. Dans le cas
où les opérations de chargement de la vis d’Archimède décrites ci-avant n’aient pas été exécutées, cela pourrait donner lieu à des
épisodes de non allumage du poêle. Vider le brasier et remettre à zero l’alarme et répéter l’allumage. Au cas où se produiraient des
non-allumages répétés, contrôler que le brasier soit logé et en parfait contact avec la base d’appuii; Verifier en outre que ne soient
pas présentes d’inscrustations qui empêchent le passage correct d’air pour permettre l’allumage.
Si le problème persiste, contacter le service d’assistance.
Modification de la puissance du poêle
L’apparition du message “REGLER SYSTEME RDS” indique que la procédure d’essai et réglage des paramètres Initial
n’est pas effectuée correctement. Cette indication n’implique pas le blocage du poêle (voir section POP UP D’INDICATION).
Séquence des phases d’allumage
ALLUMAGE – phase initiale de
chargement pellet;
ATTENTE FLAMME – phase d’attente
développement de la flame ;
PHASE FLAMME – phase de
stabilisation flamme et réduction
comburant à l’intérieur du brasier
TRAVAIL – phase de fonctionnement
Décrite dans le chapitre dédié;
En case de batterie déchargée à
l’intérieur de la “goutte” est présent un
symbole Qui indique l’état de limite de
celle-ci, tout en maintentant actives les
fonctions de l’ordinateur de poche.
Dès que le niveau de batterie ne permet
en aucune sorte la communication radio,
l’ordinateur de poche affiche plein écran
entier l’image de la batterie déchargée,
en bloquant toute les fonctions de
l’ordinateur portable jusqu’à l’effective
substitution des batteries.
Que se passe-t-il en cas de batteries déchargées
Pour les modèles avec nettoyeur automatique, pendant la phase d’allumage, le poêle active une phase de nettoyage du
brasier avant de passer à l’ALLUMAGE. En cas de NON ALLUMAGE il n’est pas nécessaire d’enlever le pellet non brûlé
À l’intérieur du brasier avant d’effectuer un nouvel allumage. Dès que l’utilisateur rallume le poêle, le système de
fonctionnement exécute l’opération sans activer le nettoyeur et sans démarrer à nouveau la phase de chargement.
Pression de la touche d’
“accès au menu” pour
accéder à la
page-écran MENU
Pression de la touche
“confirmation”
pour accéder à la
page-écran UTILISATEUR
Pression de la touche
“confirmation”
pour accéder à la
page-écran SELECTION
PUISSANCE :
A l’aide des touches “EN HAUT” et “EN BAS” il est
possible de modifier la puissance de travail.
La pression de la touche suivante permet la confirmation
de la donnée et du retour au MENU UTILISATEUR
La sélection de la puissance est effective uniquement en phase de travail du poêle. A chaque allumage celle-ci assume toujours
la puissance maximum afin de garantir le plus grand apport de chaleur à l’installation de chauffage
Sélectionner le type de gestion
Confort Clima sur la t°C
Eau ou sur la température
ambiante au moyen de la touche
flèche EN HAUT ou flèche EN
BAS
Touche “V” pour confirmer la
“sélection”
MENU
BATTERIE BASSE
BATTERIE BASSE
UTILISATEUR
TECHNIQUE
PRODUCTEUR
UTILISATEUR
REGLAGE PUISSANCE
SELECTION PUISSANCE
CHRONOTHERMOSTAT
CHARGEMENT VIS D’ARCHIMEDE
SET AIR-PELETT
MENU
UTILISATEUR
TECHNIQUE
PRODUCTEUR
UTILISATEUR
UTILISATEUR
REGLAGE PUISSANCE
ETAT POELE
CHRONOTHERMOSTAT
CONFORT CLIMA.
CONFORT CLIMA.
CONFORT CLIMA.
AIR
EAU
DELTA CONFORT
CLIMA
DELTA CONFORT
CLIMA
RETARD
EXTINCTION
RETARD
EXTINCTION
CONFORT CLIMA.
CONFORT CLIMA.
CHARGEMENT VIS D’ARCHIMEDE
CONFIGURATIONS
SET AIR-PELETT
ACTIVATION CONFORT
ACTIVATION CONFORT
ACTIVATION CONFORT
ACTIVATION CONFORT
ACTIVATION CONFORT
ACTIVATION CONFORT
GESTION CONFORT
GESTION CONFORT
GESTION CONFORT
GESTION CONFORT
DELTA REDEMARRAGE
DELTA REDEMARRAGE
DELTA REDEMARRAGE
DELTA REDEMARRAGE
RETARD EXTINCTION
RETARD EXTINCTION
RETARD EXTINCTION
RETARD EXTINCTION
User’s manual HANDHELD TOUCH RADIO
User’s manual HANDHELD TOUCH RADIO
Pag.22
Pag.23
Vers. 01 of:07.04.14
Vers. 01 of:07.04.14
Loading the auger
MENU
USER
SCREW FEEDING
SCREW FEEDING
CHRONOTHERMOSTAT
AIR-PELLET SET
STOVE STATE
USER
MANUFACTURER
ENGINEER
MENU
USER
MANUFACTURER
ENGINEER
USER
USER
COMFORT CLIMA
COMFORT CLIMA
COMFORT CLIMA
COMFORT CLIMA
ENABLE COMFORT
ENABLE COMFORT
ENABLE COMFORT
RESTART DELTA
RESTART DELTA
SHUTDOWN DELAY
SHUTDOWN DELAY
SHUTDOWN DELAY
SHUTDOWN DELAY
ENABLE COMFORT
ENABLE COMFORT
COMFORT CLIMA DELTA
COMFORT CLIMA DELTA
RESTART DELTA
SHUTDOWN DELAY
SETTINGS
SCREW FEEDING
CHRONOTHERMOSTAT
AIR-PELLET SET
STOVE STATE
ALWAYS EMPTY THE BRAZIER BEFORE TURNING THE STOVE ON AND ALWAYS CHECK
THAT ALL NONE OF ITS HOLES IS CLOGGED NEVER EMPTY THE RBAZIER INSIDE THE HOPPER.
FIRE HAZARD.
Carry out this operation to facilitate stove’s first start operations; You should also check that you have introduced pellets
into the hopper and wait until the stove is in “SHUTDOWN” or “FINAL CLEANING” mode. The number expressed in sec-
onds indicates the rotation time of the infeed screw during the first loading cycle. Once this time has elapsed, the infeed
screw stops immediately and then pellets are emptied from the grate before turning on the equipment.
Below are given the steps for accessing the relative menu.
Press the key “access
menu” to access
the
MENU page
Press the key
“confirm”
to access the
USER page
At the end of the auger loading, the display shows 0 “and automatically switches to the USER menu page.
Press the key for several times until the Stand-by page is displayed.
Setting operating temperature and power:
Set the two values following the indications given in the chapter “Description of thr display”
Turning the device on
Keep the key ON/OFF pressed for a few seconds to turn on the stove.
Press CONFIRM to enable
the rotation of the auger
The appearance of the message “ADJUST THE RDS SYSTEM” indicates that the initial parameter testing procedure
and calibration has been unsuccessfully. This indication does not cause stove blockage (see the SIGNALLING POP UP
section).
On the display of the handheld set appears the following:
Press and hold the ON/OFF button to turn off the stove door, and reset any alarms triggered.
In case the infeed screw operations described avobe have not been executed, the stove may fail to turn on. In this case,
carry out the operations described above and empty the brazier and reset the alarm.
If the stove still fails to turn on, check that the grate is properly installed and perfectly adherent to the base, and also check that
there are no deposits that prevent the smooth passage of air to enable ignition. If the problem persists, contact the support ser
-
vice.
Sequence of ignition phases
SWITCH-ON- initial pellet loading phase;
WAIT FLAME - flame
development wait
phase;
FLAME PRESENT - flame stabilization
phase and reduction of combustible
inside the brazier;
What happens if the batteries are empty?
If the battery is discharged, within the
“drop” is shown a symbol that indicates
that the battery is empty, while maintain-
ing active the features of your device.
WORK - operation phase
described in
the dedicated chapter;
As soon as the level of the battery
prevents the radio communication the
handheld set displays on full screen the
picture of empty battery and all device
functions are locked until the batteries
are replaced
CONNECT AN EXTERNAL THERMOSTAT WITH A SIMPLE DRY CONTACT, THEREFORE, NOT POWERED. MORE-
OVER, WE RECOMMEND YOU USE A THERMOSTAT WITH A MINIMUM OFFSET OF 3°C IF YOU INTEND TO USE
THE COMFORT CLIMA FUNCTION.
Operating phases of the appliance
Modulation
During the work phase, the appliance should reach the room temperature set; when this condition is met, the stove switches to
MODULATION mode in which fuel consumption and ventilation are minimum.
If you wish to detect the ambient temperature by means of an external thermostat (optional), this must be connected to
the appropriate connector on the rear side of the stove; and you will have to activate the reading in “SETTINGS - EN -
ABLE THERMOSTAT.” On display appears the writing TON / TOFF based on thermostat request.
Comfort climate
The activation of this function enables the stove to reduce pellet consumption by activating the modulation phases, after the desired
temperature has been reached. Subsequently, the stove checks that the temperature is maintained steady for a preset time. If this
condition is met, it automatically switches off, and on display appears the writing ECO.
The stove turns on again when the temperature drops below the set threshold.
Below are given the steps for accessing the relative menu.
Press the key
“access menu” to
access
the
MENU page
Press the key
“confirm”
to access the
USER page
Once you have accessed the Climate Comfort menu, it is possible to operate on the 3 types of settings dedicated to the function:
Press the key for several times until the Stand-by page is displayed.
Press the key “selection” for
“selection”
to switch to the second page
of USER MENU and select
CLIMATE COMFORT.
Press the “menu access”
button to access the
MENU screen.
Press the “confirm”
button to access the
USER screen
Press the “confirm”
button to activate feed
screw rotation
Содержание Infinity Plus 7
Страница 41: ...DATA INTERVENTO EFFETTUATO MANUTENZIONE...
Страница 75: ...DATE WORK PERFORMED MAINTENANCE...
Страница 109: ...DATE INTERVENTION EFFECTU E ENTRETIEN...
Страница 178: ......
Страница 179: ......