This type of installation (Fig. 6.6) requires a
horizontal section to connect to a pre-existing
chimney pot.
Respect the slope indicated in figure, in order
to reduce the ashes depositing in the horizontal
tube. In the lower part of the chimney pot, there
is a “T” type fitting installed with inspection cap,
in the same was as the chimney pot opening.
It is prohibited to install a 90° bend for the initial
segment, since the ashes would quickly obstruct
smoke passage, causing draught problems in
the stove (Fig. 6.2).
Fig. 6.6