136
ENGLISH
If the anomalies listed below occur, the stove
automatically switches itself off:
ANOMALIES
DESCRIPTION
High/low
temperature in
the combustion
chamber
If the temperature probe at
the smoke outlet detects
temperatures that are too
high, the stove is switched
off and the relative alarm is
displayed
High flue gas
temperature
If the fan stops, the
electronic board blocks the
supply of pellets and the
alarm is displayed
Smoke fan
failure
If the fan stops, the
electronic board blocks the
supply of pellets and the
alarm is displayed
Pellet feed
gearmotor
failure
If the gear motor fails, the
product shuts down safely
and the corresponding
alarm is displayed
Cleaning
system gear
motor failure
If the gear motor fails, the
product shuts down safely
and the corresponding
alarm is displayed
Temporary
power failure
If a power failure occurs
during operation, when
the power returns the
temperature in the
combustion chamber is
checked and, if necessary,
the stove goes into cooling
mode
No ignition
If no flame develops during
the ignition phase, the stove
goes into alarm
It is forbidden to tamper with the safety
devices. Restarting the product is only possible
after eliminating the cause that caused the
intervention of the safety system. To understand
which anomaly occurs, consult this manual which
explains, depending on the alarm message that
the device displays, how to intervene on it.
If the problem persists, contact the Support
Service.
5.9.1 Minimum clearances from
combustible materials
SIDE
DISTANCE
X1 right
200 mm
X2 left
200 mm
Y2 rear
200 mm
Y1 front
> 1000 mm
Z ceiling
800 mm
Fig. 5.1
X1
Y1
X2
Z
Y2
Содержание HOOP 7 STEEL
Страница 26: ...26 ITALIANO Fig 8 28 Fig 8 29 Fig 8 30 Fig 8 31...
Страница 87: ...87 FRANCAIS Fig 8 28 Fig 8 29 Fig 8 30 Fig 8 31...
Страница 125: ...125 FRANCAIS...
Страница 149: ...149 ENGLISH Fig 8 28 Fig 8 29 Fig 8 30 Fig 8 31...
Страница 187: ...187 ENGLISH...
Страница 190: ......
Страница 191: ......