Brochure for models with FLASH motherboard
( firmware version ECT2008air - & ECT2008box - )
PAGE
6.0 OpeRatiOns LinKeD tO “FinaL CLean” phase
the purpose of the “FinaL CLean” phase is to burn all pellets in the fire pot during the extinction phase. in fact the smoke
extractor is activated at maximum revs per minute. its value is around 2700 rpm. in just a few minutes the surplus pellet is burnt
in the basket and the stove starts the cooling phase also thanks to the support of the heat exchanger running at power of 5 until
it succeeds in lowering smoke temperature to threshold pR15.
6.1 “FinaL CLean” without Re-ignition attempt
if extinction of the stove is required, the switchboard activates the “FinaL CLean” phase and behaves as follows:
eXtinCtiOn ReQUest
COnDitiOns
OpeRatiOn
DispLaY
eFFeCt
-p3 for 4 seconds
- shut off
ChROnOtheRMOstat
eCO stOp
sMOKe teMp.>pR13 FinaL CLeaning (until fol-
lowing condition)
FinaL CLeaning
OFF
sMOKe teMp.<=pR13 FinaL CLeaning (until
timer pR40)
FinaL CLeaning
OFF
after the smoke probe has reached the value set in the pR13, the tiMeR pR40 (“t-Min eXtinCtiOn”) is activated in order to check
that the flame has gone out completely.
iMpORtant!!! the tiMeR mentioned above, that can be set manually by the pR40, must have a value equal to the time needed
to extinguish the flame, even after the “Wait FLaMe” phase where the firepot must consume a large amount of pellets before
the “OFF” status.
6.2 “FinaL CLean” with Re-ignition attempt
if a Re-ignition is requested after the “FinaL CLean”, the switchboard must behave as follows:
eXtinCtiOn ReQUest
COnDitiOns
OpeRatiOn
DispLaY
eFFeCt
- p3 for 4 seconds
- ignition with
CROnOtheRMOstat
- ignition with COMFORt
sMOKe teMp.>pR13
FinaL CLeaning (until next
condition)
Fan Wait
Re-staRt
Re-staRt
t.sMOKe<=pR11
& sMOKe teMp.>pR13
FinaL CLean (until pR39 timer)
Fan Wait
Re-staRt
Re-staRt
t.sMOKe<pR13
FinaL CLean (until pR39 timer)
Fan Wait
Re-staRt
staRt
Before every staRt - Re-staRt phase, the stove carries out a further final clean according to tiMeR pR39 (“Re-ignitiOn
BLOCKage“) in order to burn all pellets inside the fire pot.
iMpORtant!!! the tiMeR mentioned above, that can be set manually by the pR40, must have a value equal to the time needed
to extinguish the flame, even at high temperatures.
22