31
Immediately
!! without time delay !!
push the “enter” button for 3 seconds
Push cursor function till display shows
AP-??
Push “enter” button for 3 seconds again
System is calibrated and back in
weighing mode
Turn indicator off and back on.
Check system by repeating by weighing with the calibration weight.
The changes should not be bigger then 2% of the truck capacity.
With a 5000 LB Lift truck errors should not be bigger than 100LB
If weight readings are continuously higher or lower:
Check if scale shows zero when doing a weighing cycle without weight.
Repeat zero and weight calibration.
If no improvement, see chapter 7.