background image

Check the zero reading 

before each weighing!

Before each weighing it is necessary to 

check whether the system is unloaded 

and free.

If the indicator does not determine the 

zero point automatically, it must be 

done manually using the >0< key. 

Wrong way of lifting the load 

 

 

Correct way of lifting the load

      

     

USER MANUAL

 – 

RAVAS-5200

 

11

Содержание 5200

Страница 1: ...product is 100 recyclable on the basis that the parts are processed and disposed of in the right manner More information can be found on our website www ravas com Rev 20200102 Printing Typographical e...

Страница 2: ...nstructions or from negligent operation or assembly even if this is not expressly stated in this instruction manual In light of our policy of continuous improvement it is possible that details of the...

Страница 3: ...are PT 16 5 6 Net weighing reset tare two options 17 5 6 1 Option 1 17 5 6 2 Option 2 17 5 7 Activate and edit ID Code 18 5 8 Adding print clear memory send data 20 5 8 1 Add weight to subtotal 20 5 8...

Страница 4: ...m must be approved in writing by the supplier prior to any work being completed It is the sole responsibility of the purchaser to train their own employees in the proper use and maintenance of this eq...

Страница 5: ...r to stop charging Battery or charger does not work properly exchange battery or charger Storing and or using the battery outside the given temperature range may have a negative effect on the lifetime...

Страница 6: ...harging after repeated use and after time has passed If the operating time that the battery can be used becomes shorter and shorter it has probably reached the end of its life Note For replacement or...

Страница 7: ...ck The power supply to the system takes place through an exchangeable battery pack With a completely charged battery pack the total weighing time is about 25 hours for a Li ion battery for a system wi...

Страница 8: ...anging battery 4 1 Low battery indication RAVAS 5200 An exchangeable battery pack supplies power to the RAVAS 5200 When the voltage level of the battery pack is running low the battery indicator will...

Страница 9: ...nd a smart charger After charging for at least 8 hours the charger will shut off when the battery pack is completely full The red LED on the adapter will change to green once the battery is fully char...

Страница 10: ...5 Use 5 1 Use accurate weighing USER MANUAL RAVAS 5200 10...

Страница 11: ...ng it is necessary to check whether the system is unloaded and free If the indicator does not determine the zero point automatically it must be done manually using the 0 key Wrong way of lifting the l...

Страница 12: ...is unloaded while setting a new zero Out of level Make sure the pallet truck is horizontal Bad calibration No calibration has been saved Scale 1 or reference scale Weight indication Active ID s Custo...

Страница 13: ...messages Whenever a weighing was not done correctly the weight will turn red and the error is displayed Error Out of level Level switch measures scale is 3 out of level Overload The system has been o...

Страница 14: ...et Tare Gross weight 5 5 1 Net weighing automatic tare 1 2 3 4 EXPLANATION Net 1 Tare 2 Gross 3 1 2 3 The indicator is set to zero The NET sign shows that the tare weight is activated Tare 25kg shows...

Страница 15: ...ws the net value of the load weight The gross weight is displayed again NOTE for OIML approved RAVAS 5200 the tare will be erased automatically when the weight returns to gross zero For the next weigh...

Страница 16: ...ears Select the desired Preset Tare field If the preset tare you select is empty you have to enter the tare value Confirm with Enter Name your Preset Tare value The NET sign shows that the tare weight...

Страница 17: ...ghing mode and is ready for the next weighing NET sign is gone In the tare field None is active 5 6 1 option 1 5 6 2 option 2 Press the preset tare button Select none NOTE For OIML approved RAVAS 5200...

Страница 18: ...ress the ID field On the left side of the button you can activate the ID fields only the active ID fields will be visible on the printout If you press on the right side of the button an ID entry field...

Страница 19: ...fter entering one or more ID codes select your preferred ID and press the back button Press the back button to return to the weighing mode Your active ID codes will now be showed on the print out or w...

Страница 20: ...8 1 Add weight to subtotal If preferred you can select a total memory The weight is added Load scale Press the key The weight has been added to the selected total memory Select your preferred total me...

Страница 21: ...Load scale Press the printer key The indicator is now printing The weight is printed and the indicator is ready for the next weighing 5 8 4 Send WiFi First a new weight must be on the display Press t...

Страница 22: ...d press the settings symbol Press Print Total to get a total print out of the selected total register The indicator is printing your receipt If this is shown the connection is lost The weight will be...

Страница 23: ...you want to reset the active total memory after printing press OK Press Clear if you wish to erase all information in this total register Or go back if you don t wish to change the register Change the...

Страница 24: ...bol The basic weight symbol is green This means that piece counting has not been activated Press the pcs symbol This symbol now turns green to indicate that piece counting is activated 5 9 1 Activate...

Страница 25: ...Manual piece weight Enter the piece weight and confirm with Enter The number of pieces are shown in the display 5 9 2 Enter piece weight manually For entering the piece weight manually or calculating...

Страница 26: ...ill be added or removed from the scale e g 2 Confirm with Enter Note the weight difference should be at least 5 10 kg Press 5 9 3 Calculate piece weight Select Sample PCS weight W1 MAIN 3 4 Automatica...

Страница 27: ...er will start automatically As long as the image of the USB stick is green data are being transferred Once the image is white again the transfer has finished When the USB stick is connected to your PC...

Страница 28: ...5200 28 5 11 Change the time and date Press arrow down Press on the arrow up down Press the user settings symbol Select User menu Select the parameter you wish to change For this example we change th...

Страница 29: ...USER MANUAL RAVAS 5200 29 Enter the correct hour Change the cursor to the next value by pressing on the When you are finished press Enter 7 8...

Страница 30: ...Button Functions Select the button you wish to change For this example we take the print button Select Function Check the boxes of the actions you want to happen after pressing the Printer button When...

Страница 31: ...r menu Select the button you wish to move Printer button for this example If a button is not in use because in this example the printer is installed after delivery The default location is None Select...

Страница 32: ...on the indicator they are back Follow the following steps if you wish to always hide the buttons Go into the user menu Select Display settings The checkbox for Key Functions is checked meaning the bu...

Страница 33: ...ormat hh mm 3 Gross weight displays the gross weight For example 233 5 kg or 136 5 lb 4 Net weight displays the net weight For example 233 5 kg or 136 5 lb 5 Tare weight displays the tare weight For e...

Страница 34: ...3 5 7 6 4 Press the settings symbol Now press User Menu The information of the last weighing is shown on the display By pressing Prev you switch to weighings performed prior to the last weighing Pres...

Страница 35: ...his is to avoid damage to electronics and load cells The bearings of the wheels non polyurethane and the pivoting points of the levelling bar of the loading wheels must be cleansed and greased regular...

Страница 36: ...after which it can be imported in a spreadsheet program on a PC From the app you can enter the ID of an operator or device enter tares automatically or manually zero the weighing system Date and time...