2. Connect the flexible pipes (
Fig. 11 pos. 1
)
preassembled on the mandrel rotary distributor (
Fig.
11 pos. 2
), on the valve (
Fig. 11 pos. 4
) hosenipple
(
Fig. 11 pos. 3
). Fasten the pipes (
Fig. 11 pos. 1
)
with the prepared clamps (
Fig. 11 pos. 5
)
3. Connect the pipe (
Fig. 11 pos. 14
) from the greaser
reduction gear filter (
Fig. 11 pos. 7
)(air not lubri-
cated) to the compensation balancing valve (
Fig. 11
pos. 15
).
4. Connect the pipe (
Fig. 11 pos. 11
) from the pedal
board lower valve (
Fig. 11 pos. 12
) to the blow valve
(
Fig. 11 pos. 4
) union (
Fig. 11 pos. 13
).
5. Connect the pipe (
Fig. 11 pos. 6
) to the T coupling
(
Fig. 11 pos. 8
) and the coupling (
Fig. 11 pos. 16
)
placed on the tank (
Fig. 11 pos. 9
).
6. Connect the pipe (
Fig. 11 pos. 18
) from the blowing
unit (
Fig. 11 pos. 17
) to the pedal board (
Fig. 11
pos. 12
) upper union (
Fig. 11 pos. 10
).
10.0 ASSEMBLY AND PREPARATION
FOR USE
After having freed the various components from the pack-
ing check that they are complete, and that there are no
anomalies, then comply with the following instructions
for the assembly of the components making use of the
attached series of illustrations.
10.1 Assembly procedure
Remove the packaging and free the machine from the
wrapping. Lift the machine and position it on the floor.
The location of the machine requires a usable space of
3450x2500, mm (as indicated in
Fig. 8
).
The positioning of the machine must be according to the
distances shown. From the control position the opera-
tor is able to observe all the machine and surrounding
area. He must prevent unauthorized personnel or ob-
jects that could be dangerous from entering the area.
The machine must be fixed on a flat floor surface, pref-
erably of cement or tiled.
Avoid un-solid or irregular surfaces.
The base floor must be able to support the loads trans-
mitted during operation.
This surface must have a strength of at least 500 kg/m
2
.
The thickness of the solid floor must be sufficient to
guarantee that the anchoring bolts hold.
8.3
Lighting
The machine does not require its own lighting for nor-
mal working operations.
However, it must be placed in an adequately lit environ-
ment.
For correct lighting, use lamps having total power 800/
1200 Watt as envisaged by UNI 10380.
9.0
ANCHORING SYSTEM
The packed machine is fixed to a pallet by support feet.
Such feet also fix the machine to the ground through
anchor small blocks as shown in
Fig. 9
.
The holes in the solid floor must be about 10 cm deep
with a diameter of 8 mm.
The bolts (
Fig. 9 pos. 1
) must be inserted in the holes
and fully tightened.
Fig. 9
a
=762 mm
b
=410 mm
c
=525 mm
Fig. 10
Only for I version
1. Mount the tank (
Fig. 10 pos. 1
) on the base lower
part, as shown in
picture 10
, using the screws (
Fig.
10 pos. 2
) (tightening torque approx. 8 N·m), the
washers (
Fig. 10 pos. 3
) and the nuts (
Fig. 10 pos.
4
).
Содержание G8641 Series