Operation QUANTRON-K2
4
36
Figure 4.8:
Run calibration operating screen
[1] Display of elapsed time since starting the calibration
5.
Press the
Start/Stop
key again.
The calibration is ended.
The metering slide closes.
HydroControl
option: Agitator and spreading disc are stopped.
The display shows the
Input collected weight
menu.
Recalculating the flow factor
6.
Weigh the collected weight (taking into account the empty weight of the
collecting vessel).
NOTICE
The calibration can be stopped at any time by pressing the
ESC
key. The me-
tering slide closes and the display shows the
Spreading mat. settings
menu.
NOTICE
The calibration test time is not relevant to the accuracy of the results. However,
a minimum of 20kg
should be collected.
n
WARNING
Risk of injury due to rotating machine components
Contact with rotating machine components (agitator, spreading
disc) may cause bruises, abrasions and crushing injuries. Body
parts or objects may be caught or pulled in.
Switch the tractor motor off.
Switch off the PTO shaft and secure it against unauthorised
activation.