35
© 2 0 0 3 d i r e c t e d e l e c t r o n i c s , i n c .
sensor will affect both zones simultaneously. To adjust the
sensor, turn the adjustment screw on the side of the control
module.
■
For a more sensitive setting turn the adjustment screw clockwise
in small increments, testing the sensitivity after each adjustment
until the desired setting is achieved.
■
For a less setting turn the adjustment screw counter clockwise in
small increments, testing the sensor after each adjustment until
the desired setting is achieved.
step 13
Testing the system
With all the previous steps completed, the operation of the
system can now be tested.
■
Close all the doors and press the
button on the transmitter,
the system should chirp one time and the doors will lock if con-
nected. At this point the system will go through diagnostics, a
15 second process in which the security system will analyze the
status of all connected zones.
■
After 15 seconds unlock the driver side door with the key and
open the door, the alarm should emit a series of chirps to indi-
cate a security breach, after several chirps the system will go into
full trigger and the siren will sound.
■
At any point during the chirps or full trigger press the
but-
ton again and the system should turn off and the doors should
unlock if connected.
➜