32
The resistance of primary coil: 1.0-1.5 Ω
(recommended value)
(Secondary side)
Remove the cap of spark plug, to connect one end of the tester to HV harness, and make
contact between the other end and coil core, to measure resistance value on the secondary side
of the coil.
The resistance value of secondary coil: 5-7 kΩ
(recommended value)
4-4-7 Charging coil detection
Test the continuity of each pair of wires
The insulation resistance of each wire shall be ≥ 10 mΩ