Descaling the moisturing nozzle
46 / 61
Please check the moisturing nozzle for scale residue once a month.
step
info/button
instructions
1
Switch the unit off
2
Swing the hanging rack and the air baffle into
the centre.
3
Loosen the union nut on the moisturing nozzle
(turn anti-clockwise – spanner size 15).
Warning!
Aggressive chemical liquid – risk of chemical
burns!
Wear: protective clothing, safety goggles,
protective gloves, face mask.
Following descaling, rinse the moisturing nozzle
thoroughly with water.
4
Place the moisturing nozzle in the descaling
liquid and allow it to react (moisturing nozzle
must be free of scale)