- 76 -
Before you call customer service
Error:
Possible cause
To eliminate
The unit does not indicate a
function after it is switched
on.
External main switch is
switched off.
Fuse on the premises’
distribution board has
tripped.
The ambient temperature
after switching the unit off
remained below 5 °C (41 °F)
for a long time.
Switch on at the main switch.
Check the fuses on the premises’ distribution
board. Heat the cooking cabinet to above 20 °C
(68 °F).
The appliance must only be used in frost-free
conditions (see installation instructions).
Foam forms on the unit at
the top of the outlet pipe
during CleanJet
®
+care
cleaning.
Water too soft.
The outlet is not installed
correctly.
Please notify Customer Service.
Install the outlet as described in the installation
manual.
The run time is suddenly
incremented once more
during a CleanJet
®
+care
process.
The CleanJet
®
+care process
is interrupted.
Make sure that the air baffle and the grid
shelves are fixed correctly in the cooking
cabinet. There must be no containers or
sheets in the cooking cabinet during the
CleanJet
®
+care process.
The gas unit indicates
"Change polarity”.
The power supply is not
connected with the correct
polarity.
If the gas unit is connected to a socket, remove
the connector and turn through 180°.
Have an electrician permanently connect
the unit with the correct polarity (without a
connector).
Gas unit constantly displays
Reset.
The gas supply to the unit is
interrupted.
The gas pressure is too low.
Open the gas valve.
Switch on the ventilation cover.
Have the gas supply to the unit checked.
Cooking mode button
flashing
The cooking cabinet is too
hot
Use Cool Down to cool the cooking cabinet (see
the “Cool Down” section of the “General User
Instructions” manual).
Содержание SelfCooking Center