12 | Initial start-up
80.06.070_iCombi Pro-iCombi Classic_IM_V01_en-GB
83 / 92
After installing the unit, affix the sticker indicating the maximum rack height at a
height of 1600 mm [63 inches] to the unit. The sticker is provided in the starter
kit.
12.2 Perform the self-test
DANGER
Changed CO / CO
2
values after the self-test
Risk of poisoning due to excessive exhaust gas values.
n
Conduct a flue gas analysis after the selftest.
n
Set the values pursuant to the flue gas analysis provisions.
When first commissioning the unit, the selftest must be started once. During the
selftest, the unit adapts to the ambient conditions.
The selftest runs automatically. The duration depends on the unit size and is
between 45 and 65 minutes. With an UltraVent exhaust hood, the selftest is ex-
tended by around 20 minutes.
Preparations
n
The unit must be properly connected to water, waste water, and electricity
as described in this manual; gas models must also be connected to gas sup-
ply and flue exhaust lines.
n
Check the side racks and the air baffle to ensure they are seated correctly.
n
The left side panel is closed.
n
For the selftest, one GN container is required per fan wheel.
Insert the GN container
1. Insert one flat GN container in front of each fan wheel into the middle of the
hook ladders, with the opening facing the bottom.
>>
For unit sizes 6-2/3 GN up to 6-2/1 GN, there is a GN container located in
the middle of the hook ladder in front of the fan wheel.
>>
For unit sizes 10-1/1 GN and up to 10-2/1 GN, there are 2 GN containers
in the hook ladders, one in front of each fan wheel.