5 | Placement
80.06.070_iCombi Pro-iCombi Classic_IM_V01_en-GB
35 / 92
3. Secure the grub screw to the castors with a hexagon socket wrench.
Attach the mobile base frame
NOTICE
Damage to electrical or gas lines due to shifting
Also secure the unit against shifting to the rear wall with a chain or rope
(chain is not included in the delivery).
5.3
Installation of standalone units
5.3.1 Installing and aligning standalone units
Lift and set up standalone unit from transport pallet
CAUTION
Risk of tipping when installing the unit
Risk of crushing if the unit tips onto persons.
n
Note the centre of mass of the unit.
n
Make sure that the unit does not tip over from the pallet during
installation.
CAUTION
Risk of injury due to the weight of the unit
Personal injury and damage to property due to tipping over of the unit
n
At least 2 people are required to set up the unit.
a
The installation surface is level, clean and free of grease.
a
The carrying aid is available.