Ratio io7 Скачать руководство пользователя страница 5

Safety 

 |  

5

+44 (0) 1527 396900 / [email protected] / www.ratioev.uk

Please make sure the instructions have been fully read and understood before commencing 
the installation or use of the product. Failure to follow the instructions from this manual can put 
people, surroundings, the environment and product at risk. Store this manual securely for future 
reference.

Always comply with the information, such as labels and the nameplate, attached directly to 
the product and keep the information in a legible condition.

Always comply with any applicable laws and regulations that have not been accounted for in 
this manual for example IET regulations.

1.1.1.  Safety warnings

This manual contains safety warnings that may result in injury if ignored. Each safety 
warning is indicated with a safety identifier. The identifier corresponds with the level of risk of 
the described hazardous situation, see the table below.

1.1.2. Notices

Messages that are not hazard-related are indicated with the safety identifier 

NOTICE

. These 

messages do not have a safety alert symbol.

Safety warnings at the start of a section apply to the entire section.
Safety warnings that refer to a particular sentence or procedure step are embedded in the 
running text.

Medium 

 

Could result in death or serious injury

Could result in damage to the product when instruction is ignored or not 
followed correctly.

Note

Additional information or emphasis on an instruction.

Low   

 

Could result in minor or moderate injury

1.1.  Symbols and labels

   Safety 

 

Risk of injury  

Result when instruction is ignored or not followed  

 

 

 

 

Identifier 

    correctly

   Signal word 

Meaning

1. Safety

Содержание io7

Страница 1: ...1 44 0 1527 396900 info ratioev uk www ratioev uk io7 Installation Guide...

Страница 2: ...www ratioev uk Thank you for choosing the io7 Ratio EV Charging Unit 1 Target Park Shawbank Road Lakeside Redditch Worcestershire United Kingdom B98 8YN 44 0 1527 396 900 info ratioev uk sales ratioev...

Страница 3: ...t Copyright The content of this manual is protected by copyright and other intellectual property laws The content of this manual may only be copied modified reproduced or translated with express writt...

Страница 4: ...rking Transport and Storage Transport Storage Installation Preparation Required tools Required wiring and electrical protection Install the power cable in the distribution board Installing the io7 Com...

Страница 5: ...ult in injury if ignored Each safety warning is indicated with a safety identifier The identifier corresponds with the level of risk of the described hazardous situation see the table below 1 1 2 Noti...

Страница 6: ...ocket This is to inform the user the fuel type electricity produced by this charger and to instruct which end of the Electric Vehicle charging cable is to be plugged into the socket of the charger The...

Страница 7: ...d take the necessary measures to protect persons and property have received adequate training in the safe installation and maintenance of this product hold the relevant qualifications The following is...

Страница 8: ...operly grounded Do not use this product if it does not function according to the instructions in this manual Seek advice from Ratio your vendor or a qualified electrician Do not attempt to remove the...

Страница 9: ...ssional lighting systems which have been designed in acordance to BS EN 60598 1 and BS EN 62196 The io7 is equipped with several features to optimise power consumption and charging performance The io7...

Страница 10: ...ensions 1410mm 230mm 230mm Weight 17 kg Country of Manufacture United Kingdom Enclosure rating IP54 Ambient temperature 25 C to 40 C Markings CE UKCA Earthing PME fault detection on single and three p...

Страница 11: ...1527 396900 info ratioev uk www ratioev uk io7 Lighting Head Socket 1 Socket 2 Tamper proof fixing Tamper proof fixing Lower access door Upper access door Socket 1 indicator LED Socket 2 indicator LE...

Страница 12: ...hite Boot up Purple Cable inserted Blue pulsing Charging Green Ready Amber Waiting to charge Red Fault Amber pulsing Charging delayed LED Colour Status The LEDs on the io7 provides the user with a vis...

Страница 13: ...edditch B98 8YN UK PNr io7xxx 2x22kW IP54 25 C 40 C 09 2023 230 3x230 400VAC 32A 50Hz Prod SNr XXXXXXX Conn SNr XXXXXXXXXXXXXX 230 volts Danger ISOLATE BEFORE REMOVING COVER Warning ISOLATE BEFORE REM...

Страница 14: ...circuits that reference to ground no insulation resistance testing should be conducted on the unit after connecting to the supply network Spirit level Flat head screwdriver size 3 HM5 Pin Hex Allen ke...

Страница 15: ...stall the power cable in the distribution board 5 3 Installing the io7 1 Prepare the foundations of the ground prior to installing the io7 ensuring it is free from debris as well as any possible water...

Страница 16: ...400 mm Z 300 mm Foundation Dimensions PN 3440A Sep 21 165 dia GB Do not stare at operating lamp May be harmful to the eyes FR Ne pas fixer la lampe en fonctionnement DE Vermeiden Sie den direkten Blic...

Страница 17: ...Performing this test whilst the io7 is fully terminated could cause serious damage to the charger Performing this test whilst the io7 is fully terminated could cause Locking Nut Earthing Banjo Cable...

Страница 18: ...booted 2 Using a mobile device or laptop search for the chargers Wi Fi Hotspot as illustrated below 7 Close the door and secure using the HM5 Pin Hex Allen Key Ensure Earth cable is connected remains...

Страница 19: ...eb browser on a mobile device or laptop and input 10 7 10 7 into the URL search bar This should take you to the page below Alternatively scan the QR code which will navigate you directly to the site N...

Страница 20: ...e t 2 Earth C Ratio EV Charging Target Park Shawbank Rd Redditch B98 8YN UK PNr io7xxx 2 x 22kW IP54 25 C 40 C 09 2023 230 3x230 400VAC 32A 50Hz Prod SNr XXXXXXX Conn SNr XXXXXXXXXXXXXX 230 volts Dan...

Страница 21: ...details such as the charger make and model the System IP Address and the Host name 6 1 2 General Information Page Note Each charge point will have a unique password This will be located within the ch...

Страница 22: ...sconnected accordingly 2 Ensure the toggle is set to Authorisation via CSMS Server if a back end software is being used If no back end software example image below is required set to Local Authorisati...

Страница 23: ...DHCP will allow you to set either a Static or Dynamic IP dependant on requirements 2 If Wi Fi is required enable the toggle 3 Select Refresh list to view available Wi Fi networks and select your requi...

Страница 24: ...ould be between 6 63A This is the maximum available current within the installation 3 Enter the Installer Name Company and Email in the relevant cells 4 Select the Phase connection to the charger from...

Страница 25: ...Installation 24 44 0 1527 396900 info ratioev uk www ratioev uk Select save all configuration calibrate...

Страница 26: ...seconds This setting forces the charger to offer power to a vehicle anywhere between a 0 and 10 minute interval The randomised delay can be overridden if required for instantaneous charging To do this...

Страница 27: ...6 2 Back end software Provider The io7 will now be visible to the back end software The back end software instruction should be followed to finalise the commissioning Note Before the charger is ready...

Страница 28: ...ID the settings must be adjusted within the back end software provider and enable the RFID feature Once activated simply plug the charging cable into the io7 and the vehicle and activate the charging...

Страница 29: ...om periodic cleaning of the housing 9 3 Stop charging The charging session will stop automatically when the vehicle is charged to the maximum battery level set within the EV You can also manually stop...

Страница 30: ...product not approved in writing by Ratio EV Charging Any evidence of an attempt to disassemble the io7 Charger will void this warranty Any service repair outside the scope of this limited warranty sha...

Страница 31: ...Installation 30 44 0 1527 396900 info ratioev uk www ratioev uk 15 EC Declarations of Conformity...

Страница 32: ...Installation 31 44 0 1527 396900 info ratioev uk www ratioev uk...

Страница 33: ...Declaration of conformity 32 44 0 1527 396900 info ratioev uk www ratioev uk Notes...

Страница 34: ...of conformity 33 44 0 1527 396900 info ratioev uk www ratioev uk Ratio EV Charging Unit 1 Target Park Shawbank Road Lakeside Redditch Worcestershire B98 8YN 44 0 1527 396 900 ratioev uk info ratioev u...

Отзывы: