35
MIX Table
To navigate the menu follow the instructions in the picture on the left.
According to your iX3M model you can set:
iX3M Easy:
up to 2 mixes Oxygen % from 21% to 99%
iX3M Deep:
up to 3 mixes
Mix 1: %O
2
from 18% to 99% %He from 0% to 50%
Mix 2-3: %O
2
from 18% to 99%
iX3M Tech+:
up to 10 mixes (%O
2
from 05% to 99%; %He from 0% to 95%)
iX3M Reb:
up to 10 mixes (%O
2
from 05% to 99%; %He from 0% to 95%)
WARNING: Diving with Enriched air mixes or with Trimix requires a specific
training. Diving with EAN or Trimix without a suitable training or without the
due cautions is dangerous! If you have not received the specific training do not
change the MIX settings and do not dive with EAN or Trimix!
Set mixes are considered in the decompression calculations. Do not set mixes
that are different from the mixes that you will use in your dive!
O2%: It Indicates the
Oxygen % contained inside the mix.
HE%: It Indicates the
Helium % contained inside the mix.
ATTENTION: The mix cannot be higher than 100%
(e.g. if He% is 0 press
D
if you set He% at 95% the O2%will be automatically set at 5%)
PpO2:
(Partial O2 pressure): It indicates the maximum PPO2 whith which you
intend to use the mix.
MIx TAblE
MIx 1
O2%
HE%:
PPO2:
MOD:
b
A
C
D
ExIT
NExT
ENTRY
+
_
21
0
1.40
56
NEXT =>
MIx TAblE
MIx 2
O2%
HE%:
PPO2:
MOD:
DECO:
b
A
C
D
ExIT
NExT
ENTRY
+
_
50
0
1.60
22
NO
NEXT =>
Select the command NEXT => and press
D
to go to the next MIX