5. START-UP AND OPERATIONS
Lubricants must never be mixed with other substances.
Before mixing different types of lubricants always ask the manufacturer on
the compatibility of the lubricants.
5.1 GREASE QUANTITY
TABLE ‘C’
GREASE QTY. (Kg)
Sr. No.
COUPLING SIZE
RGD
RGS
1
10
0.03
0.015
2
15
0.06
0.030
3
20
0.17
0.085
4
25
0.23
0.115
5
30
0.34
0.170
6
35
0.45
0.225
7
40
0.79
0.395
8
45
1.08
0.540
9
50
1.59
0.795
10
55
1.93
0.965
11
60
3.46
1.730
12
70
6.35
3.175
13
80
9.6
4.8
14
90
13.3
6.65
15
100
17.3
8.65
RECOMMENDED GREASE – RATHI SPECIAL GREASE (RSG) , EXXON MOBIL EP2 ,
ESSO - HMP , BEACON 2 OR 3, SHELL (
δ
g = 910 Kg/m3)
If the grease quantity filled is not in accordance with the specified quantity,
the coupling may become an explosion hazard.
5.2 PROCEDURE BEFORE START-UP
Bolt tightening torques for the coupling and tightening torques for the
foundation bolts of the coupled machine must be checked before
startup. Enclosures (coupling protection, contact guard) must be fitted.
Overload conditions during startup cannot be excluded. If the
coupling breaks through overload, metal parts may fly off and cause
personal injury and/or material damage.