Page 5
1.
Ensure that AC and DC power are both OFF.
2.
Mount the inverter securely and permanently in one of the acceptable orientations.
a. Use hardware appropriate for your installation type, orientation, and location.
b. Reference Appendix 1 for orientations.
3.
Connect the equipment grounding terminal to the equipment ground bus.
4.
AC power cable is pre-wired, verfiy connections are secure.
a. Reference Color Codes in Figure 1.
5
. Mount the battery securely and permanently using the included wall bracket.
6.
Plug in the device that requires power into the AC plug connector on the front of the inverter.
7.
Connect the pre-wired quick connectors for the battery and inverter together, matching black to black and red to red.
Note:
Battery must be mounted within 4 feet of inverter.
8.
Plug inverter into AC power source.
Note:
Allow up to 12 hours for the battery to fully charge after installation.
Appendix 1
Acceptable Orientations (Mounting Template Included):
1. Under a horizontal surface.
2. In a horizontal position on a vertical surface.
3. On a horizontal surface.