Items Needed for Installation
Installation
1.
Remove 12 security screws from unit
2.
Remove top cap from unit
3.
Pull front assembly away from back unit
4.
Disconnect the gray Wago connector (see diagram on page
8
)
5.
If wall mount, mount to wall
6.
If pole mount, attach unit to pole using Pole Mounting Bracket (RP7700098A)
7.
Connect the electrical conduit of the 110vac power supply to the Call Station and run necessary wires
8.
Connect 110vac wiring to the Call Station power cable (see diagram on page
8
)
9.
Turn on 110vac power to the Call Station
Once the electrical is “live”, the phone needs to be programmed and tested. Reconnect the Wago connectors that
attach the front plate to the NEMA 4 box. If the phone will be programmed remotely, secure the front assembly to the
back panel and reinstall the 12 screws to the sides of the unit. If the phone will be programmed on-site, proceed to
the directions for “On-Site Programming”.
Communication
Page 4
Item
Description
Wall Mounting Hardware
If Mounting to Wall
Pole Mount Bracket (Part # RP7700098A)
If Mounting to Pole
#1 Phillips Screwdriver
Voltage Meter
Security Torx Bit
Provided by RATH
®
Adjustable Wrench
120v Power Source
Analog Phone Line
If Using Landline
Phone Cable
If Using Landline
Landline:
To connect your analog phone line to the Emergency Call Station:
1.
Remove front Stainless Steel plate using the security torx bit to remove the 6 security screws.
2.
Locate the gray phone cable coming out of the NEMA 4 box.
3.
Connect the incoming phone line by connecting the tip and ring of the phone line to red and green of
provided gray line cord.