background image

Ratek WBx000D Series Water Bath - User Manual 

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

 

 

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ 

Page 1 of 21

 

 

User Manual 

 

Heated Digital Water Bath 

Applicable Models : WB200D, WB500D, WB1100D, WB1700D 

Version: 1.0 – 29/02/2016 

English 

 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

www.ratek.com.au

 

 

60 Wadhurst Dve, Boronia, Victoria 3155, Australia - P: +613 9887 2161 - F: +613 9887 2163 - E: 

[email protected]

 

© All Rights Reserved 

 

Made in Australia, User Manual printed in Australia 

Changes without prior notification reserved 

Errors and omissions excepted.

 

   

 U

se

r M

an

ua


 

 

 

 

   

   

   

   

   

   

   

  

W

B

x0

0

0

D

 S

er

ie

s –

H

ea

te

D

ig

ita

l W

at

er

 B

at

Содержание WB 000D Series

Страница 1: ...rsion 1 0 29 02 2016 English www ratek com au 60 Wadhurst Dve Boronia Victoria 3155 Australia P 613 9887 2161 F 613 9887 2163 E sales ratek com au All Rights Reserved Made in Australia User Manual pri...

Страница 2: ...uct to ensure it has not been damaged in transit Any damage should be reported immediately to the responsible carrier If the product is damaged in any way re pack the product into the supplied packagi...

Страница 3: ...eral Operation 4 OPERATOR RESPONSIBILITY SAFETY CONSIDERATIONS 4 Conditions of Operation 4 Safety Labels And Markings 5 OPERATING PROCEDURES 6 Identification of Controls Functions 6 Safety Warnings 7...

Страница 4: ...e water bath is operated via a front panel interface consisting of heating temperature control buttons plus digital display and an on off switch located at the rear of the bath These controls allow th...

Страница 5: ...s or questions relating to operator or user safety please contact the appropriate Ratek Service department before installing and operating the unit Contact details are provided in this User Manual Saf...

Страница 6: ...ing a control or component of the water bath will be used to identify it The figure below indicates all key controls and components of the water bath with their corresponding numerical element labeled...

Страница 7: ...place safety regulations in effect CAUTION If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired CAUTION The equipment must on...

Страница 8: ...emptying NEVER operate the equipment if you believe it is damaged in any way NEVER operate the water bath if the mains power supply cable is damaged in any way NEVER use any sharp or metal objects ne...

Страница 9: ...into the water bath ALWAYS use plastic stainless steel or plastic powder coated tubes racks and accessories in the water bath This will assist to prevent corrosion and thus help to extend the useful l...

Страница 10: ...ated to match the power requirement as identified on the product identification label on the rear panel A surge protected power outlet is strongly recommended as it provides some protection for the eq...

Страница 11: ...if contact with the element is made Setting the Required Water Temperature The water heating control circuit will retain the last used temperature set point set on the control panel so for many appli...

Страница 12: ...y glove when removing the lid as the lid may be hot enough to cause burns or other injury NEVER remove the lid with your face directly over the water bath Steam may be present and burns or injury coul...

Страница 13: ...placed below the level of the water bath on a firm hard flat surface If emptying into a sink or drain ensure you have clear and unobstructed access to it If the bath is fitted with a drain tap models...

Страница 14: ...ferring to the section in this User Manual labeled Filling The Water Tank and allow 1 minute for the bath to cool The water bath can now be re operated as per the section of this User Manual labeled S...

Страница 15: ...mple substances that may compromise the integrity or function of electrical insulation electrical components stainless steel components or water seals Ratek and the manufacturer are consulted prior to...

Страница 16: ...ous injury or risk to life Refer the equipment to an authorized service technician for repair Over Temperature Safety Cutout Test The over temperature safety cutout should be tested periodically to en...

Страница 17: ...to the up position marked with a circle and refill the water tank with 1 000mL of cold water to cool the element by referring to the section in this User Manual labeled Filling The Water Tank This wil...

Страница 18: ...to 2 000 Metres Temperature 5 Celsius to 40 Celsius Ambient temperature will limit the minimum achievable water temperature Maximum relative humidity 80 for temperatures up to 31 Celsius decreasing l...

Страница 19: ...ng The Water Bath provides a simple to operate user interface when used in conjunction with this User Manual If at any stage you experience abnormal operation anything other than that described in thi...

Страница 20: ...n approved repairer or Ratek Instruments at the discretion of Ratek Instruments The limit of liability shall extend to the repair of the product only all other compensation claims are excluded from th...

Страница 21: ...he unit to ensure safety for the service technicians Pack the unit into it s original packaging with the supplied mains power lead and use all original protective inserts If the original packaging is...