background image

21

B

 Basic operation

2

  Press 

 to select 

the desired mode.

DRY

AUTO

COOL

1

  Press 

 to start/

stop the operation.

POWER

• When the unit 

is ON, 

 

disappears from 

the remote control 

display. 

3

  Press TEMP UP, TEMP 

DOWN to select the desired 

temperature.

Up

Down

Selection range: 

16.0 °C ~ 30.0 °C / 

60 °F ~ 86 °F.
• Press 

 for 

approximately 10 seconds 

to show the temperature as 

°C or °F.

Table of Contents

Safety Precautions ........

22-29

How to Use ...................

30-31

To Learn More... .................

32

Cleaning the 
Air Conditioner ....................

33

Troubleshooting ............

34-36

Information .........................

37

Accessories

• Remote control
• AAA or R03 batteries × 2
• Remote control holder
• Screws for remote control 

holder × 2

The illustrations in this manual are for 
explanation purposes only and may differ 
from the actual unit. They are subject to 
change without notice.

Thank you for purchasing 

Rasonic Air Conditioner.

English

Содержание RS-LU9ZK

Страница 1: ...please read these operating instructions thoroughly and keep them for future reference Before installation the installer should Read the Installation Instructions then request the customer keep them f...

Страница 2: ...EN 2 1 1 2 AAA R03 3 8 A 1 5 12 am pm 24 2 ON OFF SET TIMER CANCEL OFF ON AIR SWING TEMP OFF ON MODE SLEEP FAN SPEED QUIET POWERFUL ECO ON OFF TIMER CANCEL AIR SWING SLEEP FAN SPEED QUIET POWERFUL EC...

Страница 3: ...3 B 2 DRY AUTO COOL 1 POWER ON 3 TEMP UP TEMP DOWN 16 0 C 30 0 C 60 F 86 F 10 C F 4 11 12 13 14 15 16 18 19 AAA R03 2 2 Rasonic...

Страница 4: ...4...

Страница 5: ...5 ON Ni Cd ELCB RCD ELCB BS...

Страница 6: ...6 nanoe G R32 Amin m Amin m A R32 R410A R22 R32 R22 R32 R22 R32 R410A R32 R410A R32 R410A R22 R32 R410A 1 2 R32 R410A AHU a b c d...

Страница 7: ...7 e f g h i j 5 0 25 1 04 MPa 4 15 MPa 1 A Amin m 12 2 2 1 2 2 2 2 2 8 2 2...

Страница 8: ...8 2 3 2 4 CO2 2 5 2 6 2 7 2 8...

Страница 9: ...9 6 7 5 1 04 MPa 4 15 MPa 0 25 LFL 25 8 3 4 5...

Страница 10: ...10 10 a b c d e f g h 80 i j k 11 8 OFN OFN OFN OFN 9 OFN 7...

Страница 11: ...11 12...

Страница 12: ...O ON OFF SET TIMER CANCEL OFF ON AIR SWING TEMP OFF ON MODE SLEEP FAN SPEED QUIET POWERFUL ECO FAN SPEED QUIET FAN SPEED AUTO FAN QUIET FAN SPEED QUIET POWERFUL 20 ECO POWERFUL ECO POWERFUL ECO OFF ON...

Страница 13: ...EP POWERFUL ECO FAN SPEED QUIET POWERFUL ECO POWERFUL QUIET FAN SPEED 0 5 1 2 3 4 5 6 7 8 9 OFF 0 0h SLEEP ON OFF SET TIMER CANCEL 1 2 3 1 TIMER ON TIMER OFF 22 00 OFF OFF 2 3 SET ON OFF CANCEL ON OFF...

Страница 14: ...14 AUTO POWER COOL DRY COOL 26 0 C 28 0 C 79 F 82 F COOL DRY COOL DRY C F DBT WBT DBT WBT COOL 32 89 6 23 73 4 46 114 8 26 78 8 16 60 8 11 51 8 16 60 8 11 51 8 DBT WBT...

Страница 15: ...15 AUTO OFF ON nanoe G H 99 pH 7 40 C 104 F nanoe G nanoeTM G 2 2 1 2 2 AUTO OFF ON nanoe G 1 3 4...

Страница 16: ...16 POWER TIMER ON 15 TIMER ON nanoe G COOL nanoe G nanoe G...

Страница 17: ...17 AUTO OFF ON 1 2 AUTO OFF ON AUTO 3 COOL AUTO OFF ON 4 AUTO OFF ON 5 AUTO OFF ON COOL 15 COOL 8 C 14 4 F nanoe G 2 3...

Страница 18: ...14 H 15 H 16 CT H 17 H 19 H 21 H 23 1 H 24 2 H 25 H 26 ION H 27 H 28 1 H 30 H 31 H 32 2 H 33 H 34 H 35 H 36 H 37 H 38 H 39 H 41 H 50 H 51 H 52 H 58 H 59 H 64 H 67 nanoe H 70 H 71 H 72 H 79 H 85 H 97...

Страница 19: ...19 Pb...

Страница 20: ...oximately 5 seconds to show the time as 12 hour am pm or 24 hour 2 Press to confirm Use the remote control within 8 m from the remote control receiver on the indoor unit Provides maximum comfort and c...

Страница 21: ...ely 10 seconds to show the temperature as C or F Table of Contents Safety Precautions 22 29 How to Use 30 31 To Learn More 32 Cleaning the Air Conditioner 33 Troubleshooting 34 36 Information 37 Acces...

Страница 22: ...plosive or flammable atmosphere Failure to do so could result in fire Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit rotating parts may cause injury Do not...

Страница 23: ...lectric shock nanoe G generator Do not touch the sharp pin which may cause injury Power supply Do not use a modified cord joint cord extension cord or unspecified cord to prevent overheating and fire...

Страница 24: ...eal the opening by pinching taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use...

Страница 25: ...the precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised...

Страница 26: ...ernally into the atmosphere 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the...

Страница 27: ...the atmosphere from a leak 5 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also t...

Страница 28: ...minimize the amount of refrigerant contained in them Cylinders shall be kept in an appropriate position according to the instructions Ensure that the refrigerating system is earthed prior to charging...

Страница 29: ...employed Ensure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refri...

Страница 30: ...etter energy saving without sacrificing comfort To switch between POWERFUL ECO POWERFUL ECO exit setting nanoe G starts automatically when the unit is turned on with OFF ON OFF ON This operation can b...

Страница 31: ...operation has the priority over OFF timer This operation can be cancelled by pressing the respective button until the sleep timer reaches 0 0h SLEEP How to Use To set the timer ON OFF SET TIMER CANCEL...

Страница 32: ...fixed at middle position setting Once the temperature is achieved the horizontal flap swings up down automatically In COOL DRY mode The horizontal flap swings up down automatically Auto restart contr...

Страница 33: ...from the drain pipe nanoeTM G Generator Once every 2 weeks Clean with dry cotton bud Do not touch during operation Air filters Once every 2 weeks Wash rinse the filters gently with water to avoid dam...

Страница 34: ...ation of some plastic parts Discoloration is subjected to the types of materials used in plastic parts It is accelerated when exposed to heat sun light UV light or environmental factors After extended...

Страница 35: ...ote control is missing or a malfunction has occurred above After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14 4...

Страница 36: ...sensor 2 abnormality H 33 Indoor outdoor misconnection abnormality H 34 Outdoor heat sink temperature sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe te...

Страница 37: ...be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved WARNING This symbol shows that this equipment uses a mildly f...

Страница 38: ...Memo...

Страница 39: ...Memo...

Страница 40: ...Printed in Malaysia Panasonic Corporation 1006 Oaza Kadoma Kadoma City Osaka 571 8501 Japan Website http www panasonic com Panasonic Corporation 2022 ACXF55 35710 SY0822 0...

Отзывы: