Rasmussen RF-LD30/36-VMV-N Скачать руководство пользователя страница 9

9

 

 

PLACEMENT OF REMOTE RECEIVER  

 

Volcanic Ash 

used for floor  

dressing 

Embers spread 

over Volcanic Ash 

in burner pan 

FIGURE 10 

 

RF-LD 60/72-VEI-

Propane

 Model below prior to log placement 

Natural Gas 

Model shown below  and  How to position Battery Pack outside the fireplace. 

   RH2  

Remote 
house 

 

C) Volcanic  

     Ash used as  

     Floor dressing. 

 Volcanic Ash 

used to help conceal 

Flex connector  

and wiring 

BATTERY PACK PLACEMENT  

    NOTE:  Any beeping or unexpected shutdown may be the over-temperature safety feature in the receiver.  If this 

happens, move the receiver into a cooler area, and/or use the RH2/RH3 remote house. 

Battery Pack   

WARNING 

Battery pack needs to be installed outside the 

firebox and as far away as possible to assist 

in battery life and prevent overheating.     

Failure to follow these instructions can void 

warranty. 

CAUTION: 

DO NOT BLOCK AIR VENTS 

DOING SO WILL OVERHEAT CONTROLS AND 

VOID WARRANTY 

(Remove this paper before operating burner) 

   RH3  

Remote 
house 

 

   

RH2  

Remote 

Volcanic Ash 

used to help 

conceal Flex 

connector  

              FIGURE 11 

WARNING 

When using a Remote Control, Battery pack 

needs to be installed outside the firebox and 

as far away as possible to assist in battery life 

and prevent overheating. Failure to follow 

these instructions can void warranty. 

CAUTION: 

DO NOT BLOCK AIR VENTS 

DOING SO WILL OVERHEAT CONTROLS AND 

VOID WARRANTY 

(Remove this paper before operating burner) 

Optional 

Optional 

Содержание RF-LD30/36-VMV-N

Страница 1: ...d in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with type of gas indicated on the rating plate INSTALLER Leave this...

Страница 2: ...epair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to exc...

Страница 3: ...6 1 Rating I D Plate 2 Flex Connector SSCB 14 RF LD30 36 RF LD 42 48 3 3 8 x 1 2 FIP Flared Brass Fitting A1 5 Orifice Spud 01 XX see page 12 for size 6 Orifice Holder Internally Tapped 3 8 x 3 8 Flar...

Страница 4: ...27 29 26 Wireless ON OFF remote control with thermostatic and countdown timer features THR MV1 Optional 27 Millivolt Valve V11Z N 5 0 Nat P 10 5 Propane 28 JPG9 N Natural Gas P Propane 29 Toggle Switc...

Страница 5: ...and ventilation air must conform with The National Fuel Gas Code ANSI Z223 1 NFPA54 or The CSA B149 1 Natural Gas and Propane Installation Code latest edition STEP ONE PREPARATION 1 Verify that the Va...

Страница 6: ...iew MINIMUM FIREPLACE FLUE REQUIREMENTS The minimum permanent free opening of the fireplace chimney or chimney damper must be at least the minimum Chimney Area shown below based on a minimum chimney h...

Страница 7: ...propane gas burner A Natural Gas B Propane STEP TWO Sprinkle a light covering of Ember Magic over the Pan Medium Figure 6A and Figure 6B Pull apart Ember Magic fiber material to enhance the glowing em...

Страница 8: ...charred burnt effect between the two halves Figure 8 and Figure 9 Place the Longest Log or 2 largest charred logs if applicable Figure 8A and 9A as far forward on the Grate as possible The remaining l...

Страница 9: ...ouse Battery Pack WARNING Battery pack needs to be installed outside the firebox and as far away as possible to assist in battery life and prevent overheating Failure to follow these instructions can...

Страница 10: ...OFF FIGURE 1 FIGURE 2 FIGURE 3 A Connecting Accessory Controllers Using the 20 accessory control wiring attached to the two outside terminals of the valve block Figure 5A and 5B connect the Switch Co...

Страница 11: ...which have been closed or are obstructed with debris will not allow sufficient combustion air into the burner Use compressed air and or a soft bristle brush to clean the air mixer area Air mixers sho...

Страница 12: ...l Odor of Gas Combustion Most likely causes Lack or fresh air and or impurities in the room air Since the appliance is drawing its combustion air from the living area any odors or impurities present i...

Страница 13: ...The maximum liability of RASMUSSEN in connection with this limited warranty shall not in any case exceed the contract price paid for the product claimed to be defective or unsuitable 4 This warranty...

Отзывы: