Rasmussen RF-LD30/36-VMV-N Скачать руководство пользователя страница 3

3

 

 

PARTS LIST

 

REQUIRED TOOLS AND MATERIALS 

 

Adjustable Wrench and Pipe Wrench. Pipe Sealing compound is 

required

 if fittings not already pre-threaded with Teflon tape to  

prevent gas leaks.  

DO NOT 

use Teflon tape or pipe compound on other tapered fittings.

 

11 

 

10.   Ember Magic (

EMX1) 

11.  Black Volcanic Ash (Propane burners) 

12.   Flex Connector (

SSCB-12-18

)RF-LD60//72 ONLY) 

13.   1/2” Flared x 1/2” MIP brass elbow 

 

14.   1/2” Male flared x 1/2” MPT Half Union

 

15.   1/2” Close Nipple

 

16.   1/2” 90 degree Street  Elbow

 

17.   1/2” 90 degree Elbow

 

18.   Orifice spud Holder 3/8” x 3/8”

 

19.   1/2” x 3/8” hex bushing 

 

20.   1/2” Black Tee Fitting 

 

21.   Orifice Chart 

1.  Burner  Grate Assembley (RF-LD60//72,          

RF-LD 42/48, RF-LD30/36) 

1.  Rating/I.D. Plate  

2.  Flex Connector (

SSCB-14

)RF-LD30/36,  RF-LD 42/48) 

3. 

3/8” x 1/2” FIP Flared Brass Fitting (

A1

5.  Orifice Spud 

01-XX(

see page 12 for size)  

6. 

Orifice Holder  (Internally Tapped, 3/8” x 3/8” Flared MIP 

Fitting) (A2T) 

7.    Air Mixer for 

Propane

 Gas burners  

        (

MA2)

 

8.  Damper Clamp (

DC1)

 

9.  White Silica Sand (Natural Gas burners) 

 

18 

15 

17 

16 

14 

12 

10 

The construction of your RF-LD burner may differ slightly depending on whether it is Natural Gas or Propane and on 

which type of safety control mechanism and valve is used. 

RF-LD60/72-N/P 

(7 SQUARE BARS) 

Picture of burners Natural & Propane 

RF-LD42/48-N/P 

(5 SQUARE BARS) 

RF-LD30/36-N/P 

(4 SQUARE BARS) 

Match lite

 

(

-

N)NG Orifice(s)

 

BTUs

 

(

-

P) LP Orifice(s)

 

BTUs

 

RF

-

LD30/36

-

VMV

Top 32   Bottom 48

 

50k

 

Top 53    Bottom 59

 

35k

 

RF

-

LD42/48

-

VMV

Top 25   Bottom  28

 

60k

 

Top 51     Bottom 57

 

50k

 

RF

-

LD60/72

-

VMV

Top 1/4  Bottom 30

 

85k

 

Top 45    Bottom 53

 

80k

 

13 

20 

18 

17 

21 

19 

20 

Содержание RF-LD30/36-VMV-N

Страница 1: ...d in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with type of gas indicated on the rating plate INSTALLER Leave this...

Страница 2: ...epair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to exc...

Страница 3: ...6 1 Rating I D Plate 2 Flex Connector SSCB 14 RF LD30 36 RF LD 42 48 3 3 8 x 1 2 FIP Flared Brass Fitting A1 5 Orifice Spud 01 XX see page 12 for size 6 Orifice Holder Internally Tapped 3 8 x 3 8 Flar...

Страница 4: ...27 29 26 Wireless ON OFF remote control with thermostatic and countdown timer features THR MV1 Optional 27 Millivolt Valve V11Z N 5 0 Nat P 10 5 Propane 28 JPG9 N Natural Gas P Propane 29 Toggle Switc...

Страница 5: ...and ventilation air must conform with The National Fuel Gas Code ANSI Z223 1 NFPA54 or The CSA B149 1 Natural Gas and Propane Installation Code latest edition STEP ONE PREPARATION 1 Verify that the Va...

Страница 6: ...iew MINIMUM FIREPLACE FLUE REQUIREMENTS The minimum permanent free opening of the fireplace chimney or chimney damper must be at least the minimum Chimney Area shown below based on a minimum chimney h...

Страница 7: ...propane gas burner A Natural Gas B Propane STEP TWO Sprinkle a light covering of Ember Magic over the Pan Medium Figure 6A and Figure 6B Pull apart Ember Magic fiber material to enhance the glowing em...

Страница 8: ...charred burnt effect between the two halves Figure 8 and Figure 9 Place the Longest Log or 2 largest charred logs if applicable Figure 8A and 9A as far forward on the Grate as possible The remaining l...

Страница 9: ...ouse Battery Pack WARNING Battery pack needs to be installed outside the firebox and as far away as possible to assist in battery life and prevent overheating Failure to follow these instructions can...

Страница 10: ...OFF FIGURE 1 FIGURE 2 FIGURE 3 A Connecting Accessory Controllers Using the 20 accessory control wiring attached to the two outside terminals of the valve block Figure 5A and 5B connect the Switch Co...

Страница 11: ...which have been closed or are obstructed with debris will not allow sufficient combustion air into the burner Use compressed air and or a soft bristle brush to clean the air mixer area Air mixers sho...

Страница 12: ...l Odor of Gas Combustion Most likely causes Lack or fresh air and or impurities in the room air Since the appliance is drawing its combustion air from the living area any odors or impurities present i...

Страница 13: ...The maximum liability of RASMUSSEN in connection with this limited warranty shall not in any case exceed the contract price paid for the product claimed to be defective or unsuitable 4 This warranty...