background image

HOW TO ORDER PARTS

Parts can be ordered through the supplier from whom
you purchased your log set.
When ordering parts, always specify (From information
available on name plate attached to grate) the following:

1. Model number of the log set.
2. Serial number of the log set.
3. Type of gas (natural or propane Gas).
4. The name of the part and part number from parts list.

Save these instructions

Manufactured By:  RASMUSSEN IRON WORKS,  INC. 

12028 E. Philadelphia Street
Whittier, California  90601

CONSUMER RECORD CARD

Fill in blanks below for your permanent record.

DATE PURCHASED                

              

              

              

MODEL NO.

              

              

              

            

DATE INSTALLED

              

              

              

              

S E R I A L   N O .

              

              

              

              

INSTALLED BY:

              

              

              

              

G A S   T Y P E :

              

              

              

              

DEALER:

              

              

              

            

1

6

3

4

5

7

9

1 0

2 0

2 2

3 1

3 0

2

8

3 2

4 0

4 1

4 2

4 3

PARTS LIST C2A/C2B (MANUAL/SWITCH/REMOTE)

1 1

1 2

1 3

1 4

1 5

1 6

1 7

1 8

1 9

2 1

4 4

3 3

.

1.

Top Log Small (Left)

11.

Front Burner Orifice (N) or

17.

Rear Burner (038 or CH-5)

C2-A/B-M (Manual)

2.

Top Log Small (Right)

(LP)

18.

Supply Manifold Tubing 3/8"

30.

IRegulator Input Fitting

3.

Top Log Large (Left)

12.

Front Burn. Orifice Holder

19.

Pilot Manifold Tubing

31.

Regulator (N) or (P)

4.

Top Log Large (Right)

13.

Rear Burner Orifice Holder

20.

Carry Over Tube TEE and

32.

Manual Valve

5. 

Rear Log

14.

Rear  Burner Orifice (N) or

Orifice Assembly with 1/4"

33.

Valve Knob

6.

Front Log

(LP)

Manifold Tubing

C2-A/B-S/R (Switch/Remote)

7.

Grate

15.

Rear Burner Manifold Tubing

21.

Carryover Tube

40.

Remote Box and Cover

8.

Push Button Piezo Ignitor

3/8"

22.

Ember Material

41.

Gas Valve  (S & R Model)

9.

Ember Tray

16.

O.D.S. Assembly (N) or (P)/

42.

Receiver (R Model)

10.

Front Burner (RBT or RAT)

(MV) or Standard)

43.

Transmitter (R Model)

44.

3 Way Switch (S Model)

11

Содержание K18-C2A-M-N

Страница 1: ... in a listed ventless firebox enclosure DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs Do not use this CHILLBUSTER as a Vent Free Heater in sleeping quarters bathrooms or recreational vehicles WARNING If the information in this manual is not followed exactly a fire or explosion may re...

Страница 2: ...es instructions stating it has not been tested or should not be used with unvented gas logs WARNING Any change to this heater or its controls can be dangerous Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpet...

Страница 3: ...vicing and proper operation 3 Any outside air ducts and or ash dumps in the fireplace shall be permanently closed at time of installation WARNING Do not use a blower insert heat exchanger insert or other accessory not approved for use with this heater WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Pressure Testing VENTED and VENT FRE...

Страница 4: ...e Btu Hr against Actual Btu hr Used Maximum Supportable Btu Hr 60 160 Btu Hr Actual Btu Hr Used 72 000 Btu Hr Excess Btu Hr 11 840 Btu Hr If Actual Btu Hr Used is greater than Max Supportable Btu Hr then space is CONFINED If the Actual Btu Hr Used is less than Maximum Supportable Btu Hr then space is UNCONFINED In the example because the Actual Btu Hr Used exceeds the Maximum Supportable Btu hr th...

Страница 5: ... floors between wall panels at penetrations for plumbing electrical and gas lines and at other openings WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log sets may give off carbon monoxide an odorless colorless poisonous gas Some people pregnant women persons with heart or lung disease anemia or under the influence of alcohol and persons at high altitudes are m...

Страница 6: ...with a minimum 4 inch horizontal projection beyond vertical surface ABOVE hood as provided by most major fireplace manufacturers IF YOU CANNOT MEET THESE MINIMUM CLEARANCES YOU MUST OPERATE HEATER WITH CHIMNEY FLUE DAMPER OPEN Operate as a VENTED Heater See Page Three ALL APPLICATIONS VENTED and VENT FREE OPERATION ASSEMBLY AND INSTALLATION Attaching Ember Tray 1 Attach ember tray to the front two...

Страница 7: ... tray DO NOT PLACE VOLCANIC ASH ON TOP OF THE BURNER Log Placement 1 Place the largest log FRONT LOG on the front of the grate and the second largest log REAR LOG on the rear of the grate behind the LOCATOR PINS Fig 7 and 8 2 Place both Right and Left LARGE TOP LOGs across the FRONT and REAR logs with the LOCATOR PINS inserted into the drilled holes located on the bottom of both LARGE TOP LOGs Fig...

Страница 8: ...s must also be turned OFF Remote Control or to lowest temperature setting Thermostat 3 Wait at least 5 minutes to allow gas which may have accumulated around burner to escape 4 Turn Gas Cock Dial to PILOT position 5 Depress and hold Gas Cock Dial until air is bled and gas flows to pilot SELECTOR SWITCH Figure 11 SWITCH OFF REMOTE ON ACCESS ON 6 Press Piezo Ignitor Button to light pilot Continue to...

Страница 9: ...nd operate instantly and requires you to aim and hold the transmitter for 1 to 3 seconds to operate Manual Switch from OFF to ON ON to OFF Remote Switch to REMOTE Aim press button and hold transmitter at receiver When switching from REMOTE to OFF first turn set off using the transmitter REMOTE OFF ON Manual Operation Receiver switch position ON or OFF does not require batteries Remote Operation Re...

Страница 10: ...odically cleaned of debris Use compressed air or a soft bristle brush to clear pilot and burner s air intakes Air shutters should not be altered from factory settings WARNING Failure to keep the primary air opening s of the burner s clean may result in sooting or property damage Obstructed Pilot Air Intake Ports result in an improper gas air mixture and a weak pilot flame Weak pilot flame is the N...

Страница 11: ...TS LIST C2A C2B MANUAL SWITCH REMOTE 11 12 13 14 15 16 17 18 19 21 44 33 1 Top Log Small Left 11 Front Burner Orifice N or 17 Rear Burner 038 or CH 5 C2 A B M Manual 2 Top Log Small Right LP 18 Supply Manifold Tubing 3 8 30 IRegulator Input Fitting 3 Top Log Large Left 12 Front Burn Orifice Holder 19 Pilot Manifold Tubing 31 Regulator N or P 4 Top Log Large Right 13 Rear Burner Orifice Holder 20 C...

Страница 12: ...y as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitat...

Страница 13: ...02 DUE 12 03 Title change Customer Responsibilities And Annual Maintenance page 10 standard update z21 11 2 2000 and z21 60a 2000 completed 2 02 next z21 11 update due 3 03 includeslogstyleKW switch tabs vice screw Z21 11 2aand2binstructionchangesremobilehomes fireboxesandconvertibility 13 ...

Отзывы: