background image

AGA "CHILLBUSTER II" 

12028 E. Philadelphia St. Whittier , CA 90601  U.S.A.

(562) 696-8718        FAX (562) 698-3510

E-Mail: [email protected]  Web http://www.riwinc.com

CB-2 2-03

Assembly, Installation, and Operation Instructions for Rasmussen

"Dual Burner" Manual, Switch, or Remote Control,

Natural and Propane Gas Log Room Heater Models:

18" or 24" DUAL BURNER Manual Control

(K,W,KW)(18, 24)-C2A-M-(N,P)

24" or 30" DUAL BURNER Manual Control

(K,W,KW)(24, 30)-C2B-M-(N,P)

18" or 24" DUAL BURNER Switch Control

(K,W,KW)(18, 24)-C2A-S-(N,P)

24" or 30" DUAL BURNER Switch Control

(K,W,KW)(24, 30)-C2B-S-(N,P)

18" or 24" DUAL BURNER Remote Control

(K,W,KW)(18, 24)-C2A-R-(N,P)

24" or 30" DUAL BURNER Remote Control

(K,W,KW)(24, 30)-C2B-R-(N,P)

THESE GAS LOG HEATERS ARE CERTIFIED TO THE FOLLOWING STANDARDS:

UNVENTED ROOM HEATER ANSI Z21.11.2a 2001

VENTED DECORATIVE APPLIANCE ANSI Z21.60b 2001 * CGA 2.26b-2001

Read these Instructions carefully and retain them for future use.

WARNING:   Improper installation, adjustment, alteration, service or maintenance can

cause property damage, personal injury or loss of life. Read these instructions thoroughly

before installation.  For assistance or additional information, consult your gas log dealer,

qualified installer, service agency or gas supplier.

Design certified for installation only in a  solid-fuel burning masonry or UL 127 factory-built  fireplace or
in a listed ventless firebox enclosure.  DO NOT install this appliance in a factory-built fireplace that
includes instructions stating it has not been tested or should not be used with unvented gas logs.

Do not use this CHILLBUSTER as a Vent Free Heater in sleeping quarters, bathrooms or

recreational vehicles.

WARNING: If the information in this manual is not followed exactly, a fire or explosion

may result causing property damage, personal injury or loss of life

   .

This appliance may be installed in an after
market, permanently located,
manufactured (mobile) home, where not
prohibited by local codes.

This appliance is for use with the type of
gas indicated on the rating plate. This
appliance is not convertible for use with
other gases.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do
not use any phone in your building.

Immediately call your gas supplier from
a neighbors phone. Follow the gas
supplier's instructions.

If you cannot reach your gas supplier,
call the fire department.

FOR YOUR SAFETY: Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other appliance.

   .

 Installation and service must be performed by a qualified installer, service

agency or the gas supplier.

   .

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
Refer to Section "PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION
AIR" (pages 4 and 5.)

   .

1

Содержание K18-C2A-M-N

Страница 1: ... in a listed ventless firebox enclosure DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs Do not use this CHILLBUSTER as a Vent Free Heater in sleeping quarters bathrooms or recreational vehicles WARNING If the information in this manual is not followed exactly a fire or explosion may re...

Страница 2: ...es instructions stating it has not been tested or should not be used with unvented gas logs WARNING Any change to this heater or its controls can be dangerous Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpet...

Страница 3: ...vicing and proper operation 3 Any outside air ducts and or ash dumps in the fireplace shall be permanently closed at time of installation WARNING Do not use a blower insert heat exchanger insert or other accessory not approved for use with this heater WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Pressure Testing VENTED and VENT FRE...

Страница 4: ...e Btu Hr against Actual Btu hr Used Maximum Supportable Btu Hr 60 160 Btu Hr Actual Btu Hr Used 72 000 Btu Hr Excess Btu Hr 11 840 Btu Hr If Actual Btu Hr Used is greater than Max Supportable Btu Hr then space is CONFINED If the Actual Btu Hr Used is less than Maximum Supportable Btu Hr then space is UNCONFINED In the example because the Actual Btu Hr Used exceeds the Maximum Supportable Btu hr th...

Страница 5: ... floors between wall panels at penetrations for plumbing electrical and gas lines and at other openings WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log sets may give off carbon monoxide an odorless colorless poisonous gas Some people pregnant women persons with heart or lung disease anemia or under the influence of alcohol and persons at high altitudes are m...

Страница 6: ...with a minimum 4 inch horizontal projection beyond vertical surface ABOVE hood as provided by most major fireplace manufacturers IF YOU CANNOT MEET THESE MINIMUM CLEARANCES YOU MUST OPERATE HEATER WITH CHIMNEY FLUE DAMPER OPEN Operate as a VENTED Heater See Page Three ALL APPLICATIONS VENTED and VENT FREE OPERATION ASSEMBLY AND INSTALLATION Attaching Ember Tray 1 Attach ember tray to the front two...

Страница 7: ... tray DO NOT PLACE VOLCANIC ASH ON TOP OF THE BURNER Log Placement 1 Place the largest log FRONT LOG on the front of the grate and the second largest log REAR LOG on the rear of the grate behind the LOCATOR PINS Fig 7 and 8 2 Place both Right and Left LARGE TOP LOGs across the FRONT and REAR logs with the LOCATOR PINS inserted into the drilled holes located on the bottom of both LARGE TOP LOGs Fig...

Страница 8: ...s must also be turned OFF Remote Control or to lowest temperature setting Thermostat 3 Wait at least 5 minutes to allow gas which may have accumulated around burner to escape 4 Turn Gas Cock Dial to PILOT position 5 Depress and hold Gas Cock Dial until air is bled and gas flows to pilot SELECTOR SWITCH Figure 11 SWITCH OFF REMOTE ON ACCESS ON 6 Press Piezo Ignitor Button to light pilot Continue to...

Страница 9: ...nd operate instantly and requires you to aim and hold the transmitter for 1 to 3 seconds to operate Manual Switch from OFF to ON ON to OFF Remote Switch to REMOTE Aim press button and hold transmitter at receiver When switching from REMOTE to OFF first turn set off using the transmitter REMOTE OFF ON Manual Operation Receiver switch position ON or OFF does not require batteries Remote Operation Re...

Страница 10: ...odically cleaned of debris Use compressed air or a soft bristle brush to clear pilot and burner s air intakes Air shutters should not be altered from factory settings WARNING Failure to keep the primary air opening s of the burner s clean may result in sooting or property damage Obstructed Pilot Air Intake Ports result in an improper gas air mixture and a weak pilot flame Weak pilot flame is the N...

Страница 11: ...TS LIST C2A C2B MANUAL SWITCH REMOTE 11 12 13 14 15 16 17 18 19 21 44 33 1 Top Log Small Left 11 Front Burner Orifice N or 17 Rear Burner 038 or CH 5 C2 A B M Manual 2 Top Log Small Right LP 18 Supply Manifold Tubing 3 8 30 IRegulator Input Fitting 3 Top Log Large Left 12 Front Burn Orifice Holder 19 Pilot Manifold Tubing 31 Regulator N or P 4 Top Log Large Right 13 Rear Burner Orifice Holder 20 C...

Страница 12: ...y as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitat...

Страница 13: ...02 DUE 12 03 Title change Customer Responsibilities And Annual Maintenance page 10 standard update z21 11 2 2000 and z21 60a 2000 completed 2 02 next z21 11 update due 3 03 includeslogstyleKW switch tabs vice screw Z21 11 2aand2binstructionchangesremobilehomes fireboxesandconvertibility 13 ...

Отзывы: