ALL APPLICATIONS (Installation)

ALL APPLICATIONS-IMPORTANT NOTICE

Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid 
burns or clothing ignition.

Young children should be carefully supervised when they are in the same room with the appliance.

Do not place clothing or any other flammable material on or near the appliance.

Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the heater.

WARNING: During manufacturing, fabricating, and shipping, various components of CHILLBUSTER are 
treated with certain oils or films. These are not harmful but may produce annoying smoke and smells as they are 
burned off during the initial operation of the appliance, possibly causing headaches or eye or lung irritation. This i
s a normal and temporary occurrence. The initial break-in operation should last 2-3 hours with the burner at the 
highest setting. Provide maximum ventilation by opening windows, doors, and the chimney flue to allow odors to 
dissipate. The only odor remaining after this initial break-in will be the normal odors associated with the 
combustion of Natural or Propane gas.

This appliance is equipped with an ODS (OXYGEN DEPLETION SENSOR) pilot light safety system designed to 
shut itself off if not enough fresh air is available. Additional ventilation may be obtained by opening a window or a 
door to another room.

Although your CHILLBUSTER is very realistic in appearance, it is not a real wood burning fireplace. Matches, 
paper, garbage, or any other material must not be thrown on top of the logs or into the flames.

Avoid contact with the logs, grate, or any other part which may be hot.

Always ensure that the fireplace screen is closed when the appliance is operating.

   .

ALL APPLICATIONS-IMPORTANT INSTALLATION INFORMATION

WARNING: Design certified for installation only in a  solid-fuel burning masonry or
UL 127 factory-built  fireplace or in a listed ventless firebox enclosure.  It has been
design certified for these installations.  DO NOT install this appliance in a factory-
built fireplace that includes instructions stating it has not been tested or should
not be used with unvented gas logs.

"WARNING: Any change to this heater or its controls can be dangerous."

Installation and repair should be done by a qualified service person. The appliance
should be inspected before use and at least annually by a professional service person.
More frequent cleaning may be required due to excessive lint from carpeting, bedding
material, etc. It is imperative that control compartments, burners and circulating air
passageways of the appliance be kept clean.

State or local codes may only allow operation of this appliance in a vented configuration.
Check your state or local codes. If not permitted, you may install and operate
CHILLBUSTER as a vented appliance. (See "VENTED OPERATION" page 3).

This appliance is for supplemental heating only. It should not be used as the primary heat
source for a dwelling.

Due to high temperatures, the appliance should be located out of traffic and away from
furniture and draperies.

"WARNING: Failure to keep the primary air opening(s) of the burner(s)clean may

result in sooting or property damage."

1.

This appliance may be installed in an after market, permanently located, manufactured (mobile) home, where not 
prohibited by local codes.

2.

This appliance is for use with the type of gas indicated on the rating plate. This appliance is not field convertible for 
use with other gases.  Gas type conversion may only be accomplished at the factory.

3.  Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect 

the appliance and to replace any part of the control system and any gas control which has been under water.

4.

If local valve is not already installed, install a gas valve on the supply line in or just outside the fireplace.

5.

A fireplace screen must be in place when the CHILLBUSTER is in operation and, unless other provisions for 
combustion air are provided, the screen shall have opening(s) for introduction of combustion air. Glass doors are 
not certified with the CHILLBUSTER. However, if used, Glass Doors must be wide open when the burner
is on
 to allow air for safe combustion, cooling of components and venting. Adequate clearances must be provided
around fireplace opening for adequate combustion and proper operation.  (see page 5)

2

Содержание Chillbuster Magnum Series

Страница 1: ...ier Design certified for installation only in a solid fuel burning masonry or UL 127 factory built fireplace or in a listed ventless firebox enclosure DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs Do not use this CHILLBUSTER as a Vent Free Heater in sleeping quarters bathrooms or rec...

Страница 2: ...es instructions stating it has not been tested or should not be used with unvented gas logs WARNING Any change to this heater or its controls can be dangerous Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpet...

Страница 3: ...ds Provide adequate clearances for servicing and proper operation 3 Any outside air ducts and or ash dumps in the fireplace shall be permanently closed at time of installation WARNING Do not use a blower insert heat exchanger insert or other accessory not approved for use with this heater WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame pattern...

Страница 4: ...e Btu Hr against Actual Btu hr Used Maximum Supportable Btu Hr 60 160 Btu Hr Actual Btu Hr Used 72 000 Btu Hr Excess Btu Hr 11 840 Btu Hr If Actual Btu Hr Used is greater than Max Supportable Btu Hr then space is CONFINED If the Actual Btu Hr Used is less than Maximum Supportable Btu Hr then space is UNCONFINED In the example because the Actual Btu Hr Used exceeds the Maximum Supportable Btu hr th...

Страница 5: ... floors between wall panels at penetrations for plumbing electrical and gas lines and at other openings WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log sets may give off carbon monoxide an odorless colorless poisonous gas Some people pregnant women persons with heart or lung disease anemia or under the influence of alcohol and persons at high altitudes are m...

Страница 6: ... 10 FIREBOX Figure 3 IF YOU CANNOT MEET THESE MINIMUM CLEARANCES YOU MUST OPERATE HEATER WITH CHIMNEY FLUE DAMPER OPEN Operate as a VENTED Heater See Page Three ALL APPLICATIONS VENTED and VENT FREE OPERATION ASSEMBLY AND INSTALLATION Attaching Ember Tray Models C2A and C2B 1 Attach ember tray to the front two legs of the grate with the nuts and bolts provided on grate See Figure 6 INSTALLING CHIL...

Страница 7: ...ted levels of carbon monoxide Looser pieces of Ember Material produce more efficient combustion performance and enhance the overall glowing ember effect LOG PLACEMENT ALL MODELS 1 Place largest log FRONT LOG in the front of the grate and the second largest log REAR LOG on the rear of the grate behind the LOCATOR PINS Figures 5 and 6 2 Place both Right and Left LARGE TOP LOGs across the FRONT and R...

Страница 8: ...ted around burner to escape 4 Depress and turn Gas Dial to PILOT position 5 Depress and hold Gas Dial until air is bled and gas flows to pilot Figure 11 SWITCH OFF REMOTE ON ACCESS ON SELECTOR SWITCH 6 Press Piezo Ignitor Button to light pilot Continue to hold in the Gas Dial until the Pilot flame remains lit when knob is released approx 60 to 90 seconds If Pilot does not remain lit repeat steps 1...

Страница 9: ...ESS REMOTE WITH THERMOSTAT Model IRRC WALL SWITCH Model WS 1 WALL THERMOSTAT Model TS 1 WALL TIMER 60 MINUTE TIMER Model WT 1 CRACKLER Sound Generator option for F10 AB or IRRC Model CF5 Accessory REMOTE LOG HOUSE Model RH is available for use as a heat resistant log in which the receiver portion of Wireless remote option F10 AB or IRRC may be located Accessory CRACKLER LOG HOUSE Model CH is avail...

Страница 10: ...ure and a weak pilot flame Weak pilot flame is the NUMBER 1 SERVICE ISSUE RE NUISANCE SHUT OFF Using canned compressed air pipe cleaner or an artist s brush clean out the opposing Air Intake Ports located at base of Pilot where gas supply line attaches to pilot Figures 15 and 16 Do not operate in a dirty firebox or in a previously used firebox which has not had all soot completely removed or it s ...

Страница 11: ...rifice Holder 33 Lighter Tube 44 Valve Knob 3 Top Log Right 11 Main Burner Orifice 34 Grate SWITCH REMOTE CONTROL 4 Rear Log 12 3 8 Gas Supply Connector 35 Front Burner MODELS 5 Front Log M1A or M1B MODELS 36 Ember tray 50 Receiver 6 ODS NAT or LP MV Switch 20 Grate 37 Ember Material 51 Transmitter or STANDARD Manual M2A or M2B MODELS MANUAL CONTROL MODELS 52 Switch 7 ODS Gas Supply Manifold 30 Li...

Страница 12: ...y as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitat...

Страница 13: ...CPW CB 2 96 13 ...