Each and every CHILLBUSTER that leaves the factory is quality checked to ensure compliance with our

American Gas Association certification.  This check includes an operational test to ensure both satisfactory
combustion and proper operation.

Each installation site for any vent free heater presents its own unique combustion environment.  Specific factors

such as weather tightness of the home, size of the room in which the heater is installed, central heating, ceiling fans,
drafts, altitude, the size of the firebox, paint or soot inside the firebox,
etc., all have an influence on the proper operation of any vent free gas
log set.  A normally operating CHILLBUSTER Gas Log Heater will
possess the following characteristics:

Clean burning combustion, which, after normal break in, will produce
no soot or smoke.

A full bodied, lively flame.  The flame will be blue at the base and a 
combination of blue and yellow at the body and tips. Figure 17.

Produce no odor other than the normal odors associated with the 
combustion of Natural or Propane gas.

Will produce water vapor (increase indoor humidity) which may be 
beneficial during the dry heating season.

Figure 17

Customer Responsibilities And Annual Maintenance:

• Keep the area around the CHILLBUSTER free and clear from debris. From time to time, visually check pilot and

burner flames for proper appearance (Figures 15, 16 and 17).  Normal flame color should be yellow body
surrounded by a hard blue haze.

• The pilot, air shutters and burners must be free of lint and dirt for optimum performance.  Air shutters which have

been closed or are obstructed with debris will not allow sufficient combustion air into burner.  Air shutters should be
periodically cleaned of debris.  Use compressed air or a soft bristle brush to clear pilot and burner(s) air intakes.  Air
shutters should not be altered from factory settings
"WARNING: Failure to keep the primary air
opening(s) of the burner(s)clean may result in sooting or property damage."

• Obstructed Pilot Air Intake Ports result in an improper gas/air mixture and a weak pilot flame.  Weak pilot flame is

the NUMBER 1 SERVICE ISSUE RE NUISANCE SHUT-OFF.  Using canned compressed air, pipe
cleaner or an artist's brush, clean out the opposing Air Intake Ports located at base of Pilot (where gas supply line
attaches to pilot).  (Figures 15 and 16)

• Do not operate in a dirty firebox or in a previously used firebox which has not had all soot completely removed or it's

chimney flue cleaned. Previously used fireboxes must have flue and stack professionally cleaned by a chimney
sweep.  Additionally, firebox walls and damper must also be thoroughly cleaned of all burn residue and soot using a
damp cloth, sponge or brush.

• Do not operate this set with any logs other than the RASMUSSEN CHILLBUSTER Refractory Logs specifically

designed and approved for use with this Burner System.

• Do not use with blower inserts or heat exchangers.
• If used, glass doors must be wide open when burner is on.
• Do not remove Rating Plate/Warning Tags. These tags serve you and any future user as an integral safety and

identification component of the CHILLBUSTER gas log heater.  Removing these tags voids the warranty.

• WARNING:  Do not allow fans to blow directly into fireplace.  Avoid any drafts that alter burner

flame patterns. Do not place blower inside area of firebox. Ceiling fans may create drafts that alter burner flame
patterns. Sooting and improper burning may occur. Sooting can settle on  surfaces outside the fireplace.

• During periods of heavy use, inspect frequently for evidence of sooting. If sooting is present, discontinue

use until source of sooting is determined and corrected.

• Maintain log positioning as shown in Figures 7 and 8 at all times.

How To Order Parts

Parts can be ordered through the supplier from whom
you purchased your CHILLBUSTER.
When ordering parts, always specify (From information
available on name plate attached to grate) the following:

1. Model number of the CHILLBUSTER.
2. Serial number of the CHILLBUSTER.
3. Type of gas (natural or propane Gas).
4. The name of the part and part number from parts list.

Save these Instructions

Manufactured By:  RASMUSSEN IRON WORKS,  INC. 

12028 E. Philadelphia Street
Whittier, California  90601

CONSUMER RECORD CARD

Fill in blanks below for your permanent record.

DATE PURCHASED                

              

              

              

MODEL NO.

              

              

              

            

DATE INSTALLED

              

              

              

              

S E R I A L   N O .

              

              

              

              

INSTALLED BY:

              

              

              

              

G A S   T Y P E :

              

              

              

              

DEALER:

              

              

              

            

10

Содержание Chillbuster Magnum Series

Страница 1: ...ier Design certified for installation only in a solid fuel burning masonry or UL 127 factory built fireplace or in a listed ventless firebox enclosure DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs Do not use this CHILLBUSTER as a Vent Free Heater in sleeping quarters bathrooms or rec...

Страница 2: ...es instructions stating it has not been tested or should not be used with unvented gas logs WARNING Any change to this heater or its controls can be dangerous Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpet...

Страница 3: ...ds Provide adequate clearances for servicing and proper operation 3 Any outside air ducts and or ash dumps in the fireplace shall be permanently closed at time of installation WARNING Do not use a blower insert heat exchanger insert or other accessory not approved for use with this heater WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame pattern...

Страница 4: ...e Btu Hr against Actual Btu hr Used Maximum Supportable Btu Hr 60 160 Btu Hr Actual Btu Hr Used 72 000 Btu Hr Excess Btu Hr 11 840 Btu Hr If Actual Btu Hr Used is greater than Max Supportable Btu Hr then space is CONFINED If the Actual Btu Hr Used is less than Maximum Supportable Btu Hr then space is UNCONFINED In the example because the Actual Btu Hr Used exceeds the Maximum Supportable Btu hr th...

Страница 5: ... floors between wall panels at penetrations for plumbing electrical and gas lines and at other openings WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log sets may give off carbon monoxide an odorless colorless poisonous gas Some people pregnant women persons with heart or lung disease anemia or under the influence of alcohol and persons at high altitudes are m...

Страница 6: ... 10 FIREBOX Figure 3 IF YOU CANNOT MEET THESE MINIMUM CLEARANCES YOU MUST OPERATE HEATER WITH CHIMNEY FLUE DAMPER OPEN Operate as a VENTED Heater See Page Three ALL APPLICATIONS VENTED and VENT FREE OPERATION ASSEMBLY AND INSTALLATION Attaching Ember Tray Models C2A and C2B 1 Attach ember tray to the front two legs of the grate with the nuts and bolts provided on grate See Figure 6 INSTALLING CHIL...

Страница 7: ...ted levels of carbon monoxide Looser pieces of Ember Material produce more efficient combustion performance and enhance the overall glowing ember effect LOG PLACEMENT ALL MODELS 1 Place largest log FRONT LOG in the front of the grate and the second largest log REAR LOG on the rear of the grate behind the LOCATOR PINS Figures 5 and 6 2 Place both Right and Left LARGE TOP LOGs across the FRONT and R...

Страница 8: ...ted around burner to escape 4 Depress and turn Gas Dial to PILOT position 5 Depress and hold Gas Dial until air is bled and gas flows to pilot Figure 11 SWITCH OFF REMOTE ON ACCESS ON SELECTOR SWITCH 6 Press Piezo Ignitor Button to light pilot Continue to hold in the Gas Dial until the Pilot flame remains lit when knob is released approx 60 to 90 seconds If Pilot does not remain lit repeat steps 1...

Страница 9: ...ESS REMOTE WITH THERMOSTAT Model IRRC WALL SWITCH Model WS 1 WALL THERMOSTAT Model TS 1 WALL TIMER 60 MINUTE TIMER Model WT 1 CRACKLER Sound Generator option for F10 AB or IRRC Model CF5 Accessory REMOTE LOG HOUSE Model RH is available for use as a heat resistant log in which the receiver portion of Wireless remote option F10 AB or IRRC may be located Accessory CRACKLER LOG HOUSE Model CH is avail...

Страница 10: ...ure and a weak pilot flame Weak pilot flame is the NUMBER 1 SERVICE ISSUE RE NUISANCE SHUT OFF Using canned compressed air pipe cleaner or an artist s brush clean out the opposing Air Intake Ports located at base of Pilot where gas supply line attaches to pilot Figures 15 and 16 Do not operate in a dirty firebox or in a previously used firebox which has not had all soot completely removed or it s ...

Страница 11: ...rifice Holder 33 Lighter Tube 44 Valve Knob 3 Top Log Right 11 Main Burner Orifice 34 Grate SWITCH REMOTE CONTROL 4 Rear Log 12 3 8 Gas Supply Connector 35 Front Burner MODELS 5 Front Log M1A or M1B MODELS 36 Ember tray 50 Receiver 6 ODS NAT or LP MV Switch 20 Grate 37 Ember Material 51 Transmitter or STANDARD Manual M2A or M2B MODELS MANUAL CONTROL MODELS 52 Switch 7 ODS Gas Supply Manifold 30 Li...

Страница 12: ...y as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitat...

Страница 13: ...CPW CB 2 96 13 ...

Страница 14: ...CHANGES next page 1 standard update z21 11 2a 2001 DUE 4 03 standard update z21 11 2b 2002 DUE 12 03 Title change Customer Responsibilities And Annual Maintenance page 10 next z21 11 update due 3 03 14 ...

Отзывы: