background image

12 

 

Log locator pins for; 

H14 S25  D7 

FIGURE 17 

STEP FOUR: HF18 TOP LOG AND RECEIVER PLACEMENT 

 

6. TOP LOGS  

 

      Using the log locator holes and pins, Place the 

Large Center Log  

      (S25)

 onto the 

Center Pin 

on the 

Rear Log (Figures 16 and 17)

.   

      Place the 

Small Center Log (H13) 

onto the pin on the Large  

      Center Log

 (Figures 16 and  18)

. Place the 

Left Top Log (H14)

  

      over the 

Left Pin

 and the 

Right Top Log (D7)

 over the 

Right Pin

  

      on the  

Rear Log

. (Figures 16 and 17)  

S25 

H13 

Log Locator  

Hole 

Log Locator  

Pin 

FIGURE 18 

REMOTE RECEIVER PLACEMENT 

A)  Remote Receiver 

for “RE” and “SE”  

Models   

Black Volcanic  

Ash used to help 

conceal flex  

connector  

and wiring 

The Remote Receiver (-RE and -SE models) can be adversely affected by heat and must be placed as 

far forward and 

to the side of your CHILLBUSTER™ as possible 

(Figure 19A). When connecting receiver to Motordrive (“-RE” mod-

els) or Solenoid (“SE models) be sure to match red and black connectors, red to red and black to black). Our optional  

Ceramic Log House 

accessory (Figure 19B), offers heat protection for the Remote Receiver while being pleasing to the 

eye. Also sold separately, is our “Stand Alone Crackler” which mimics the sound of a crackling fire adding a cozy feel to 

your log set. 

Black Volcanic  

Ash used as  

Floor dressing. 

H14 

H13 

D7 

S25 

FIGURE 16 

FIGURE 19 

WARNING:  

Failure to position the parts in accordance with these diagrams or failure to use only parts specifically 

approved with this heater may result in property damage or personal injury.

 

C) 

B) 

Содержание CHILLBUSTER 5

Страница 1: ...performed by a qualified installer service agency or the gas supplier WARNING If the information in this manual is not followed exactly a fire or explosion may result caus ing property damage personal injury or loss of life This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with type of g...

Страница 2: ...ted before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean WARNING Any change to this heater or its controls can be dangerous This appliance is intended for supplemental heating ...

Страница 3: ...TV KE2 20 3 8 x 1 2 FIP Flared Brass Fitting A1 21 Damper Clamp DC1 22 Flex Connector SSCB 18 23a Rating Serial Plate 23b Warning Plate 24 Variable Flame Height Motordrive RE Models STV VMD 25 Remote Ready Solenoid SE Models STV LS See following page for wireless accessories 26 Grate C5 OLD STYLE C5E 27 Heat Shield misc part 28 Pilot Assembly Natural Gas ODS OP N 29 Plot Assembly Propane ODS OP P ...

Страница 4: ...ld ON OFF Remote SR 2R b Wireless Hand Held ON OFF Remote with Thermostat THR 2R c Wireless Wall Timer 30 60 120 Minutes WT 2R d Wireless Wall Thermostat TS 2R e Wireless Wall Switch WS 2R 51 Wireless Hand Held Variable Remote for RE Models STR RMD 52 Remote Receiver for SE or RE models BPR3 41 HF30 Right Middle Log H12 42 Left Top Log for 18 and 24 Models H14 43 Middle Top Log all models S25 44 2...

Страница 5: ...crease the Actual Btu Hr used by the same amount You may also choose to operate your ALTERNA as a Vented Appliance instead See notes and warnings regarding vented installation on Page 7 Adequate Combustion And Ventilation Air Options Increasing the Maximum Supportable Btu Hr 1 Add to the number of rooms which comprise the Space To do this you must either completely remove the door to an adjoining ...

Страница 6: ...r plumbing electrical and gas lines and at other openings VENT FREE APPLICATIONS COMBUSTION AIR CALCULATIONS COMBUSTION AIR CALCULATIONS WORKSHEET 1 Room Width Length Height W x L x H Vol ft 1a 1a 1b 1b 1c 1c 1d 1d 2 Total Volume ft The Sum of Volume of all rooms add lines 1a thru 1d 2 3 Max Supportable Btu Hr Total Volume ft 50 x 1000 divide line 2 by 50 then multiply by1000 3 4 4a Btu hr 4b Btu ...

Страница 7: ...fire In most cases they should also be adequate to prevent any discoloration or warping due to heat However each and every decorative gas appliance installation CHILLBUSTER included presents a different and com pletely unique set of circumstances involving many variables beyond the control of the manufacturer These include paint or finish composition previous exposure to heat methods and quality o...

Страница 8: ... provisions for combustion and ventilation air must conform with The National Fuel Gas Code ANSI Z223 1 NFPA54 or The CSA B149 1 Natural Gas and Propane Installation Code latest edition STEP ONE PREPARATION ALL MODELS 1 Verify that the Valve Assembly is correctly matched to the set burner and gas supply 2 Insure that Fireplace Gas Supply is off Figure 1A 3 Thoroughly clean fireplace floor of any a...

Страница 9: ...Width Minimum 6 greater than log set size FIGURE 3 Long Valve Key K2 sold separately Rear Width Not less than log set size Log Locator Pins Guide Groove Guide Groove C 1 2 FIP x 3 8 Flared Elbow B Valve Input FIGURE 5 FIGURE 4 Log Locator Pins C Rear Log MINIMUM AND MAXIMUM INLET GAS SUPPLY PRESSURE The minimum inlet gas supply pressure shall be 5 inches of water column on Natural Gas and 11 inche...

Страница 10: ...oove Figure 6A with right end of Front Burner Figure 6 and 7B and position Front Log between Front Burner and Grate Teeth as shown in Figure 7C A Left Middle Log Guide Groove B Left guide Plate B Front Log Guide Groove Grate Teeth C Front Log Left Guide Plate B Right End of Front Burner Rear Bracket Front Burner Left Middle Log Left Guide Plate Rear Burner Middle Burner Right Guide Plate RightMidd...

Страница 11: ...r can result in decreased combustion performance and elevated levels of carbon monoxide STEP FOUR HF18 LOG PLACEMENT AND PAN MEDIUM Volcanic Ash Placement Volcainc Ash should only be used on the firebox floor as floor dressing Figure 14A above DO NOT place Volcanic Ash or any other material other than the Ember Material provided on top of the burners FIGURE 12 FIGURE 13 FIGURE 15 Rear Bracket Rear...

Страница 12: ...e Receiver RE and SE models can be adversely affected by heat and must be placed as far forward and to the side of your CHILLBUSTER as possible Figure 19A When connecting receiver to Motordrive RE mod els or Solenoid SE models be sure to match red and black connectors red to red and black to black Our optional Ceramic Log House accessory Figure 19B offers heat protection for the Remote Receiver wh...

Страница 13: ... position log between the Middle Burner and Rear Burner as shown in Figure 23 3 RIGHT MIDDLE LOG Align Right Middle Log Figure 24A guide groove over Right Guide Plate Figure 24B and Pilot Figure 24C Place between the Front Burner and the Middle Burner Figure 25A Rear Bracket Front Burner B Front Log Guide Groove Grate Teeth C Front Log Left Guide Plate FIGURE 21 1 FRONT LOG Align Front Log Guide G...

Страница 14: ... on the firebox floor as floor dressing Figure 28A above DO NOT place Volcanic Ash or any other material other than the Ember Material provided on top of the burners Rear Burner Rear Bracket FIGURE 27 FIGURE 28 FIGURE 29 Rear Burner Guide Groove A PAN MEDIUM 5 EMBER MAGIC With the Front Middle and Rear Logs on the Grate as shown in Figure 28 bottom left pull the Ember Magic apart into loose thin p...

Страница 15: ...E 30 The Remote Receiver RE and SE models can be adversely affected by heat and must be placed as far forward and to the side of your CHILLBUSTER as possible Figure 33A When connecting receiver to Motordrive RE mod els or Solenoid SE models be sure to match red and black connectors red to red and black to black Our optional Ceramic Log House accessory Figure 33B offers heat protection for the Remo...

Страница 16: ... Burner Front Burner B Right Guide 3 RIGHT MIDDLE LOG Align Right Middle Log Figure 38A guide groove over Right Guide Plate Figure 38B and Pilot Figure 38C Place between the Front Burner and the Middle Burner Figure 39A Ends of Front Burner B Front Log Guide Grooves FIGURE 34 FIGURE 35 1 FRONT LOG Align Front Log Guide Grooves Figure 34A with ends of Front Burner Figure 34 and 35B and position Fro...

Страница 17: ...ar Burner Guide Groove A PAN MEDIUM 5 EMBER MAGIC With the Front Middle and Rear Logs on the Grate as shown in Figure 28 bottom left pull the Ember Magic apart into loose thin pieces and completely cover the Front Middle and the right side of the Rear Burners Ember Material should be one to two pieces of ember material in depth and should uniformly cover the Burners Including the Pilot To ensure p...

Страница 18: ...o help conceal flex connector and wiring S25 H13 Log Locator Hole Log Locator Pin A D Black Volcanic Ash used as Floor dressing The Remote Receiver RE and SE models can be adversely affected by heat and must be placed as far forward and to the side of your CHILBUSTER as possible Figure 45A When connecting receiver to Motordrive RE models or Solenoid SE models be sure to match red and black connect...

Страница 19: ... least five minutes to allow gas which may have accumulated around burner to escape then slightly push in the EASY Safety Valve Knob and turn to PILOT OFF Figure 47 3 Depress knob until air dissipates and gas flows to pilot located on the right side behind the front burner Press the Piezo Ignitor Button to light the pilot Figure 48A and continue to hold knob in until pilot remains lighted after kn...

Страница 20: ...ATION RE VARIABLE FLAME HEIGHT AND SE REMOTE READY MODELS 1 Turn Valve Knob to ON position Figure 50A 2 Slide switch on the Receiver Figure 51 to REMOTE position RE Models 3 Depress the ON HI button on the TRANSMITTER Figure 50B until a click is heard The burner will then light to Full on NOTE Reducing the burner flame can be achieved by pressing the LO button one beep at a time to the desired fla...

Страница 21: ... operating the heater This appliance is equipped with a Safety Pilot System designed to shut itself off if enough fresh air is not available Additional ventilation may be optained by opening a window or a door to another room Although your CHILBUSTER is very realistic in appearance it is not a real wood burning fireplace Matches paper garbage or any other foreign material MUST NOT be thrown on top...

Страница 22: ...e flame comes out of the burner should be periodically cleaned of debris Use compressed air and or a soft bristle brush to clean burner ports and air shutter area Air shutters should not be altered from factory settings WARNING Failure to keep the burner primary air opening clean may result in sooting or property damage Keep air intake holes of ODS Pilot see Page 20 Figure 34 clear of lint Over ti...

Страница 23: ...r Relieve any tight bends or kinks in the Flex Connector Switch to a smooth aluminum connector which can be purchased at hardware or home improvement stores Burner Flame is Too High 8 12 Above Top Logs or Too Low Below Top Logs Incorrect gas supply pressure or burner orifice used 1 Ensure gas type of set is proper for gas type being used Make sure the gas pressure coming into the fireplace falls b...

Страница 24: ...of incidental or consequential damages so the above limitation or exclusion may not apply to you 3 The maximum liability of RASMUSSEN in connection with this limited warranty shall not in any case exceed the contract price paid for the product claimed to be defective or unsuitable 4 This warranty does not extend to any product manufactured by RASMUSSEN which has been subjected to misuse neglect ac...

Отзывы: