![RASHA PROFESSIONAL PHOTON Скачать руководство пользователя страница 19](http://html2.mh-extra.com/html/rasha-professional/photon/photon_user-manual_3745364019.webp)
ERROR MESSAGES
When you turn on the 600W LED pro
fi
le , it will
fi
rst perform an automatic reset.
The display may show “Err channel is XX” indicating there is a problem
with one or more of the channels. “XX” represents channel 1, 2, 3, 4, 5
or 6, which contain the testing sensor for positioning. For example, the
message, “Err channel is Pan movement”, indicates an error in channel
1. If there is an error on channel 1 and channel 3 at the same time, the
following error message may appear: “Err channel is Pan movement”, “Err
channel is Tilt movement”. The system will
fl
ash twice, and the
fi
xture will
generate a second reset. If the error message persists after more than two
resets, the channels showing errors will not work properly but the other
channels will function normally.
Please contact our company for service and do
not attempt to repair the luminaire yourself.
PAN- movement Er
(PAN-yoke movement error): This message will appear after the reset
if the yoke’s magnetic-indexing circuit malfunctions (failed sensor or
magnet missing) or the stepping-motor is defective (also caused by its
driving IC on the main PCB). The PAN- movement does not return to the
default position after the reset.
TILT- movement Er
(TILT-head movement error): This message will appear after the reset
if the head’s magnetic-indexing circuit malfunctions (sensor failed or
magnet missing) or the stepping-motor is defective (also caused by its
driving IC on the main PCB). The TILT- movement does not return to the
default position after the reset.
USER MANUAL _ 20