SETUP
Power Supply
Each
Hex Cruz
e
Bar
has an auto-ranging power supply that works
with an input voltage range of 100 to 240 VAC, 50/60 Hz. To
determine the power requirements for each
Hex Cruz
e
Bar
refer to
the label affixed to the product. You can also refer to the Technical
Specifications chart in this manual. The listed current rating indicates the
maximum current draw during normal operation. For more information,
you may download Sizing Circuit Breakers from the Rasha website:
www.rashaprofessional.com
Always connect this product to a protected circuit with an appropriate
electrical ground to avoid the risk of electrocution or fire. To eliminate
unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
Never connect this product to a rheostat (variable resistor) or dimmer circuit,
even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
AC Plug
The
Hex Cruz
e
Bar
comes with a power input cord terminated
with powerCON
®
In and out, A connector on one end and an Edison
plug on the other end (U.S. market). If the power input cord that came
with your product has no plug, or if you need to change the Edison
plug, use the table below to wire the new plug.
Fuse
Replacement
1. Disconnect this product from the power outlet.
2. Using a flat-head screwdriver, lift the fuse holder cap from the housing.
3. Remove the blown fuse and replace with a another fuse of the same
type and rating (T 5 A).
4. press the fuse holder cap back in place and reconnect power.
Make sure to disconnect the product’s power cord before replacing
a blown fuse. Always replace the blown fuse with another of the same
type and rating
DMX
Personalities
z
G
• Refer to the Introduction chapter for a brief description of each DMX
personality.
• The
Hex Cruz
e
Bar
uses a 3-pin DMX and Wireless DMX 2.4
data
connection for the 7 or 12 channel DMX personalities.
• Refer to the Operation chapter to learn how to configure the
Hex Cruz
e
Bar
to work in these personalities.
• The DMX Values section provides you with detailed information regarding
the DMX personalities
Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow or Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
If you are not familiar with or need more information about DMX standards, Master/Slave connectivity,