Pressurized Freshwater Model - Recommended Wire and Fuse/Circuit Breaker Size
4
Sea Water Model - Recommended Wire and Fuse/Circuit Breaker Size
Plumbing
CONVERSIONS
Wire - AWG to mm
2
Feet to Meters
NOTES: for Wiring
Feet 10 15 20 25 30 40 50
Meter 3.1 4.6 6.1 7.6 9.2 12.2 15.2
AWG 16
14
12
10
8
6
4
2
mm
2
1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0
Maximum suction of Intake pump
(Maximum height above waterline)
4 Ft. (1.2m) from Intake Pump.
Maximum height of discharge vented loop
6 Ft. (1.8m) from base of toilet.
Pressurized water source requirements
Minimum flow rate of 3.5 gpm (13.25 liters)
at 10psi (70 K pa)
shutoff pressure of 5 psi (34.5 kPa).
1. Distances are from source to unit and back to source.
2.
Distance from power source to remote intake pump MUST be included when
determining total distance.Same wire size MUST be used for lower base and
remote intake pump.
3. Recommended conductor wire minimum AWG (mm
2
) for 3% voltage drop.
4. Recommended conductor sizes are based on 105
o
C rated insulation.
Refer to ABYC Standards for other insulation ratings.
5. For 120/240 VAC units use 12VDC specifications from transformer to unit.
Units
Voltage
Circuit Breaker/
fuse size (amps)
Amp. draw
@ nominal voltage
10 feet
15 feet
20 feet
30 feet
40 feet
50 feet
12 VDC
Lower Base
25
13
12 AWG 10 AWG 10 AWG
8 AWG
6 AWG
6 AWG
24 VDC
Lower Base
15
7.5
14 AWG
12 AWG
10 AWG
10 AWG
8 AWG
6 AWG
12, 24, and Water Solenoid
Valve
3
2
16 AWG 16 AWG 16 AWG 16 AWG 16 AWG
16 AWG
SPECIFICA
TIONS
5
L365v0320jlc
Units
Voltage
Circuit
Breaker/fuse
size (amps)
Remote Pump
and lower base
Amp. draw
@ nominal
voltage
Remote Pump
only
Amp. draw
@ nominal
voltage
15
feet
20
feet
30
feet
40
feet
50
feet
12 VDC
25
23
10
10 AWG
8 AWG
6 AWG 6 AWG 4 AWG
24 VDC
15
12.5
5
14 AWG 14 AWG 12 AWG 10 AWG 10 AWG