671
In This Chapter
RJ45-to-DB9 Cable Requirements for Modem Connections (for iX7™ Only)
................................................................................................................. 670
Reserving IP Addresses in DHCP Servers .............................................. 671
Sensor Threshold Settings...................................................................... 675
PDView App for Viewing the PX3 ............................................................. 682
Altitude Correction Factors..................................................................... 684
Unbalanced Current Calculation ............................................................ 685
Data for BTU Calculation......................................................................... 686
Ways to Probe Existing User Profiles ..................................................... 687
Raritan Training Website......................................................................... 687
Role of a DNS Server............................................................................... 688
Cascading Troubleshooting..................................................................... 688
Browsing through the Online Help ......................................................... 694
RJ45-to-DB9 Cable Requirements for Modem Connections (for iX7™ Only)
An RJ45-to-DB9 adapter/cable is required for connecting a modem to an
iX7
™
PDU.
A third party RJ45-to-DB9 adapter/cable needs to meet the following
requirements.
RJ-45 to "DB9 male"
RX/TX and according control pins are NOT crossed
With the following pin assignments:
Pin signal
DB9 pin No.
RJ-45 pin No.
DCD 1
5
RxD 2
6
TxD 3
3
DTR 4
2
GND 5
4
DSR 6
7
RTS 7
1
CTS 8
8
RIR 9
N/A
Appendix K Additional PX3 Information
Содержание PX3-1000 series
Страница 5: ......
Страница 92: ...Chapter 4 Connecting External Equipment Optional 70...
Страница 668: ...Appendix J RADIUS Configuration Illustration 646 Note If your PX3 uses PAP then select PAP...
Страница 669: ...Appendix J RADIUS Configuration Illustration 647 10 Select Standard to the left of the dialog and then click Add...
Страница 670: ...Appendix J RADIUS Configuration Illustration 648 11 Select Filter Id from the list of attributes and click Add...
Страница 673: ...Appendix J RADIUS Configuration Illustration 651 14 The new attribute is added Click OK...
Страница 674: ...Appendix J RADIUS Configuration Illustration 652 15 Click Next to continue...
Страница 722: ...Appendix L Integration 700 3 Click OK...