Pressurized Freshwater Model - Recommended Wire and Fuse/Circuit Breaker Size

Sea Water Model - Recommended Wire and Fuse/Circuit Breaker Size

Plumbing

NOTES: for Wiring

Hose Sizes

INLET

 

1/2”(12.7 mm.)  for freshwater model

 

3/4” (19 mm.) for sea water model

Discharge

 

1”(25.4 mm.)  or 1  1/2”(38 mm.) 

CONVERSIONS

Wire - AWG to mm

2

Feet to Meters

Bowl type

A

B

C

D

E

F

G

ME-

angledback

18 3/8

(467)

12 1/4

(311)

14

(355)

12

(305)

14

(355)

8 1/2

(216)

2 1/8

(54)

ME-

straightback

18 3/8

(467)

12 1/4

(311)

14

(355)

12

(305)

14

(355)

8 1/2

(216)

NA

ME-TALL

angled back

18 3/8

(467)

12 1/4

(311)

17

(432)

15

(380)

14

(355)

8 1/2

(216)

2 1/8

(54)

ME-TALL

Straight back

18 3/8

(467)

12 1/4

(311)

17

(432)

15

(380)

14

(355)

8 1/2

(216)

NA

SIZE inch (mm.)

E

B

C

G

F

A

D

AWG

16

14

12

10

8

6

4

2

mm

2

1.5

2.5

4.0

6.0

10.0 16.0 25.0 35.0

Feet

10

15

20

25

30

40

50

Meter

3.1

4.6

6.1

7.6

9.2

12.2 15.2

1.

Distances are from source to unit and back to source.

2.

Distance from power source to remote intake pump MUST be included when

determining total distance.Same wire size MUST be used for lower base and

remote intake pump.

3.

Recommended conductor wire minimum AWG (mm

2

) for 3% voltage drop.

4.

Recommended conductor sizes are based on 105

o

C rated insulation.

Refer to ABYC Standards for other insulation ratings.

5.

For 120/240 VAC units use 12VDC specifications from transformer to unit.

Units

Voltage

Circuit

Breaker/fuse

size (amps)

Elegance

toilet

Amp. draw

@ nominal

Voltage/

Remote

Pump

Only

Amp. draw

@ nominal

voltage

15

feet

20

feet

30

feet

40

feet

50

feet

12 VDC

30

18

10

10 AWG 8 AWG

6 AWG

6 AWG

4 AWG

24 VDC

20

10

5

14 AWG 14 AWG

12 AWG

10 AWG

10 AWG

Units

Voltage

Circuit

Breaker/fuse

size (amps)

Amp. draw

@ nominal

voltage

10

feet

15

feet

20

feet

30

feet

40

feet

50

feet

12 VDC

25

18

12 AWG 10 AWG 10 AWG 8 AWG

6 AWG

6 AWG

24 VDC

15

10

14 AWG 12 AWG 10 AWG 10 AWG 8 AWG

6 AWG

L490  0720jlc                                                                                                             

Maximum  suction  of  Intake  Pump                             

(Maximum height above waterline)

4 ft (1.2m) from Intake Pump

Maximum height of discharge vented 

loop

10 ft (3 m) from base of toilet

Pressurized water source minimum         

requirements

Minimum flow rate 3 gallons      

(113 liters) per minute. Mini-

mum pressure 5 PSI (34.5 KPA)

 

Angled Back

 

Straight Back

        Tall 

Straight Back

        Tall 

Angled Back

Содержание Marine Elegance Toilet

Страница 1: ...Wireless Remote Bluetooth Control program your STC wirelessly up to 50 ft away from the toilet Eliminates the need to route wires through bulkheads and cabinetry Marine Elegance THE FOLLOWING ARE CAUT...

Страница 2: ...d connections In Line Strainer if you have one No special toilet paper is required Water should appear in the bowl within ten seconds If not see troubleshooting section Hard objects or stringy substan...

Страница 3: ...1 2 38 mm I D discharge hose approximately 3 feet 1 m long Two buckets Nontoxic antifreeze approximately 1 quart 1 liter Steps 1 Close the intake and discharge seacocks 2 Turn off power to unit 3 Dis...

Страница 4: ...ce Same wire size MUST be used for lower base and remote intake pump 3 Recommended conductor wire minimum AWG mm2 for 3 voltage drop 4 Recommended conductor sizes are based on 105o C rated insulation...

Страница 5: ...les center line and outside of the bowl FIG 1 Draw a center line between two holes Mark front hole outside and center and draw a line perpendicular to first center line 2 Mark three lines A B and C 3...

Страница 6: ...aterline Discharge Pressurized Fresh water Source Shut off Valve Waterline remote pump Electroscan Waterline Discharge Seacock Waterline Discharge Vented Loop Intake Vented Loop Discharge Seacock Inta...

Страница 7: ...ank etc Inlet Lines 1 Connect 1 2 13 mm hose to pressurized supply or 3 4 19 mm hose to remote pump Intake Lines Pressurized Freshwater Models 1 Install a shut off valve in intake line before water so...

Страница 8: ...it breaker size from Specifications on Installation page 3 Install fuse circuit breaker in positive line at source 4 Wire control to the toilet and battery using one of the wiring diagram supplied wit...

Страница 9: ...ak from bowl spud TROUBLESHOOTING SOLUTION 1A Be sure discharge seacock is open Clear line remove clog 1B Replumb to eliminate bends and ells 1C Clean holding tank vent and vented loop vents 1D Clean...

Страница 10: ...44 162415 Plug Fitting 45 162420 Fitting Retaining Clip 3 46 162425 O ring 3 47 F162VT Inlet Pump Mounting Bolt 4 48 F144 10 Washer SS Flat 4 50 PLA26 Elbow Adapter 3 4 X 1 2 PRESSURIZED FRESH WATER U...

Страница 11: ...11 EXPLODED PARTS L490 0720jlc...

Страница 12: ...n instructions or standard industry procedures physical abuse to or misuse of this product This warranty also does not cover damages to equipment caused by fire flood external water excessive corrosio...

Отзывы: