background image

3.2 Inflation & Deflation
 

3.2.1  

Set the desired pressure, refer to Section 3.1 for the function oft each Switch

 

3.2.2 

Connect the hose to the tyre, ensure the hose is connected securely. Air leaks 

 
 

 

will cause an error message to be displayed, refer to Section 4.0.

 

3.2.3 

The Pressure in the tyre will be displayed.

 

3.2.4 

The unit will inflate or defalte the tyre to the set pressure. Periodically the 

 

 

process will stop and display the pressure in the tyre.

 

3.2.5 

If the pressure in the tyre is less than 3psi, 20kPa or 0,2bar the process will not 

 

 

commence until the ‚Flat Tyre Only‘ Switch is pressed, refer Section 3.1.

 

3.2.6 

The scroll bar will indicate that the unit is inflating or deflating, see below

 

3.2.7 

When the set pressure is reached the display will flash and the unit will beep 

 

 

five (5) times. This will continue until the hose is disconnected, during this time 

 

 

the keypad will be disabled.

3.3 Volume Adjustment

 

3.3.1  

Turn off the unit

 

3.3.2 

Press and hold the Decrease and ‚Flat Tyre Only‘ switches, refer to Section 3.1.

 

3.3.3 

Turn the unit on, VOL will be displayed.

 

3.3.4 

Adjust the volume using the Increase and Decrease switches, refer to Section 

 

 

3.1.

 

3.3.5 

To store the settings press the ‚Flat Tyre Only‘ switch. Further changes can be 

 

 

made by repeating the above procedure.

6

+49 (6158) 92980-0

Содержание 89 MXA

Страница 1: ...ce procedures Upon installation pass this manual to the equipment owner i Weiterentwicklung im Sinne des Fortschrittes behalten wir uns vor Technical Modifications are subject to change Details techni...

Страница 2: ...nt 1 0 Introduction 1 1 This Manual Congratulation on selecting an Airtec Digital Tyre Inflator This equipement has a number of unique features that are explained in this manual Throughout the manual...

Страница 3: ...nal Max Inlet air supply 10 3 bar 150 psi Recom inlet air supply 0 7 bar 10 psi over max adjusted pressure of the unit Operating pressure max 10 bar 145 psi Operating pressure min 0 3 bar 5psi Accurac...

Страница 4: ...Unpack the unit an remove the front panel 2 Drill the four 4 mounting locations in the back box to suit up to M6 or 1 4 fasteners 3 Hold the unit up on the wall and mark where the four 4 holes are to...

Страница 5: ...display will immediately revert back to the default unit of measurement The pressure can only be set in the default unit of measurement Selectable Unit Mode Pressing and releasung the Switch will disp...

Страница 6: ...ce until the Flat Tyre Only Switch is pressed refer Section 3 1 3 2 6 The scroll bar will indicate that the unit is inflating or deflating see below 3 2 7 When the set pressure is reached the display...

Страница 7: ...spply pressure check the air compressor supply pressure ER1 Unstable pressure faulty hose connector replace the hose Connector ER2 Unstable pressure faulty hose connector Incorrect supply pressure Inf...

Страница 8: ...Callibration Check Callibration Error Disconnect hose connector reset machine by switching off power for 5 seconds The ER9 messagewill clear automatically wehn the factory calibration isrestored If E...

Страница 9: ...vy duty hose chucksand 1x hose coupling cover 410 702 Beeper suits89 MXA 7 0 Component Replacement 7 1 Hose Connector Clip on hose chuck The hose chuck has y screw on connector Simply unscrew the exis...

Страница 10: ...installation of digital inflation equipement is different however it is imperative with any system that the drain valves No 3 are opened routinely to remove water that has been collected Immediately...

Страница 11: ...of merchantability and fitness for any other purpose Airtec Corporation Asia Pte Ltd further excludes liability for consequential and incidental losses including but not limited to the loss of profits...

Страница 12: ...Fax 49 6158 92980 50 info rapid group de Rapid Group GmbH Bahnhofstra e 53 55 64560 Riedstadt Telefon 49 6158 92980 0 www rapid group de 12 49 6158 92980 0...

Отзывы: