1.3 General Specifications

Operating temperature

-10°C bis +40°C (14°F bis 104°F)

Relative humidity

1

Installation location

Only in closed room

Supply voltage

220-240 V 50 Hz

Current

1A max.

Fuse

Auto Reset, 1,1A nominal

Max. Inlet air supply

10,3 bar (150 psi)

Recom. inlet air supply

0,7 bar (10 psi) over max. adjusted pressure 
of the unit

Operating pressure max.

10 bar (145 psi)

Operating pressure min.

0,3 bar (5psi)

Accuracy

Up to 0,5% of total value

Display increments

0,1 bar (1psi)

Units of mesurement

bar, psi

Default to safe setting

With restarting the unit pressure preset will be 
resetted automatically to 2,2bar

+49 (6158) 92980-0

3

Содержание 89 MXA

Страница 1: ...ce procedures Upon installation pass this manual to the equipment owner i Weiterentwicklung im Sinne des Fortschrittes behalten wir uns vor Technical Modifications are subject to change Details techni...

Страница 2: ...nt 1 0 Introduction 1 1 This Manual Congratulation on selecting an Airtec Digital Tyre Inflator This equipement has a number of unique features that are explained in this manual Throughout the manual...

Страница 3: ...nal Max Inlet air supply 10 3 bar 150 psi Recom inlet air supply 0 7 bar 10 psi over max adjusted pressure of the unit Operating pressure max 10 bar 145 psi Operating pressure min 0 3 bar 5psi Accurac...

Страница 4: ...Unpack the unit an remove the front panel 2 Drill the four 4 mounting locations in the back box to suit up to M6 or 1 4 fasteners 3 Hold the unit up on the wall and mark where the four 4 holes are to...

Страница 5: ...display will immediately revert back to the default unit of measurement The pressure can only be set in the default unit of measurement Selectable Unit Mode Pressing and releasung the Switch will disp...

Страница 6: ...ce until the Flat Tyre Only Switch is pressed refer Section 3 1 3 2 6 The scroll bar will indicate that the unit is inflating or deflating see below 3 2 7 When the set pressure is reached the display...

Страница 7: ...spply pressure check the air compressor supply pressure ER1 Unstable pressure faulty hose connector replace the hose Connector ER2 Unstable pressure faulty hose connector Incorrect supply pressure Inf...

Страница 8: ...Callibration Check Callibration Error Disconnect hose connector reset machine by switching off power for 5 seconds The ER9 messagewill clear automatically wehn the factory calibration isrestored If E...

Страница 9: ...vy duty hose chucksand 1x hose coupling cover 410 702 Beeper suits89 MXA 7 0 Component Replacement 7 1 Hose Connector Clip on hose chuck The hose chuck has y screw on connector Simply unscrew the exis...

Страница 10: ...installation of digital inflation equipement is different however it is imperative with any system that the drain valves No 3 are opened routinely to remove water that has been collected Immediately...

Страница 11: ...of merchantability and fitness for any other purpose Airtec Corporation Asia Pte Ltd further excludes liability for consequential and incidental losses including but not limited to the loss of profits...

Страница 12: ...Fax 49 6158 92980 50 info rapid group de Rapid Group GmbH Bahnhofstra e 53 55 64560 Riedstadt Telefon 49 6158 92980 0 www rapid group de 12 49 6158 92980 0...

Отзывы: