Operating instructions RS wash
│
D wash
│
P wash
│
SHERAprint wash
│
3Dewash
15
│
29
Rapid Shape GmbH
│
DOCR000257
4.1
Safety during installation
DANGER!
Danger to life due to electric current!
Incorrect connection, insulation faults, foreign objects
(dust, liquid due to inappropriate installation
environment) or lack of grounding can lead to housing
parts being live. There is an imminent danger of
electrocution in the event of contact with live parts.
—
Work on the electrical equipment may only be
carried out by qualified electricians and in
compliance with the relevant safety and VDE
regulations.
—
Machines with damage to the power cord,
insulation or lack of earthing must be disconnect-
ed from the mains immediately. Repairs are to be
made immediately.
—
Connect the mains plug to the nearest and
correctly grounded socket of the machine.
—
Only operate the machine with the mains voltage
specified for the machine.
—
Only operate the machine with the power supply
unit supplied
—
The mains plug must be freely accessible at all
times. A complete separation of the machine from
the mains in an emergency by pulling out the
power plug (
→
Chapter 5).
—
Keep moisture away from live parts. This may lead
to short circuiting.
4.2
Setting up
4.2.1
Requirements for the installation location
For the smooth functioning of the machine, please note the following
requirements at the installation location:
—
dust protected room
—
sufficient fresh air supply
—
protection against direct sunlight (window equipped with UV
protection film)
—
UV-protected exposure
—
stable base (table)
—
Internet connection (LAN/WLAN)
The following optional requirements are recommended:
—
Sink with fresh water
—
Air conditioned environment