SECTION 13: VENTING - MULTIBURNER SYSTEMS
13.1 General Re
q
uirements
. All general venting
req
u
irements apply.
13.2 Manifold Tube Re
q
uirements
Manifold t
u
be is
u
sed to connect radiant t
u
bing to the
p
u
mp. When more than one b
u
rner is connected to a
p
u
mp, a special connection fitting is
u
tilized, s
u
ch as
a cross or tee section.
. It is
recommended that 4'' (10.2 cm) O.D. or 6'' (15.2 cm)
O.D. al
u
minized or coated t
u
bing be
u
sed for
manifold pipe. Reflectors are not req
u
ired, b
u
t may
be
u
sed over 4'' (10.2 cm) manifold pipe. Manifold
pipe m
u
st be s
u
pported properly,
w
ith at least one
hanger per 10' (3 m) section. Refer to
for manifold length design req
u
irements.
13.3 Venting the Pump
The exha
u
st connection from the p
u
mp is 4'' (10.2
cm) or 6'' (15.2 cm) diameter. Connect one of the
flexible isolation boots provided to the fl
u
e pipe.
Connections to the fl
u
e pipe larger than the p
u
mp
o
u
tlet diameter
w
ill req
u
ire the
u
se of an appropriate
adapter (not s
u
pplied).
Venting from the p
u
mp may discharge either
horizontally or vertically; corrosion resistant pipe is
req
u
ired.
for p
u
mp vent
length req
u
irements.
The layo
u
t dra
w
ing sho
w
s the general location of the
p
u
mp. Specific p
u
mp location and discharge details
m
u
st meet general venting req
u
irements (see
) as
w
ell as
the follo
w
ing criteria:
• To avoid staining the b
u
ilding
w
all, extend
discharge 3' (1 m) from the b
u
ilding if possible.
• Horizontal discharge is preferred,
. Vertical discharge m
u
st be arranged
as sho
w
If the vent pipe is over 20' (6 m) long, ins
u
late it to
minimize condensation. Seal all discharge pipe joints
w
ith high-temperat
u
re silicone or eq
u
ivalent.
FIGURE 28: Tailpipe Connection Points
WARNING
Carbon Monoxide Hazard
Multiburner systems are not approved for
unvented use and must be vented outdoors.
Vented heaters must be installed accordin
g
to
the installation manual.
Failure to follow these instructions can result
in death or injury.
WARNING
Cut/Pinch Hazard
Wear protective
g
ear durin
g
installation,
operation and service.
Ed
g
es are sharp.
Failure to follow these instructions can result
in injury.
10" (25 cm)
20"
(51 cm)
20" (51 cm)
20"
(51 cm)
Description
Part Number
Porcelain Coated Cross, 4'' (10.2 cm) dia
0133092D
Al
u
minized Steel Cross, 4'' (10.2 cm) dia
01330903
Al
u
minized Steel Cross, 6'' (15.2 cm) dia
01330904
Description
Part Number
Porcelain Coated Tee, 4'' (10.2 cm)
dia
0133022D
Al
u
minized Steel Tee, 4'' (10.2 cm) dia
01330203
Al
u
minized Steel Tee, 6'' dia (15.2 cm)
01330204