Positive Displacement Pump - Safety 

LN-9415-01 

SAFETY  PRECAUTIONS 

 

Before  operating,  maintaining  or  servicing  any  
Ransburg  electrostatic  coating  system,  read 
and  understand  all  of  the  technical  and  safety 
literature  for  your  Ransburg  products.  This 
manual  contains  information  that  is  important 
for  you  to  know  and  understand.  This  infor-
mation  relates  to  USER  SAFETY  and  PRE-
VENTING  EQUIPMENT  PROBLEMS.  To  help 
you recognize this information, we use the fol-
lowing symbols. Please pay particular attention 
to these sections. 
 

A WARNING! states information to alert you 
to a situation that might cause serious inju-
ry if instructions are not followed. 
 
A  CAUTION!  states  information  that  tells 
how  to  prevent  damage  to  equipment  or 
how  to  avoid  a  situation  that  might  cause 
minor injury. 
 
A  NOTE  is  information  relevant  to  the  pro-
cedure in progress. 

 
While  this  manual  lists  standard  specifications 
and  service  procedures,  some  minor  devia-
tions may be found between this literature and 
your equipment. Differences in local codes and 
plant  requirements,  material  delivery  require-
ments,  etc.,  make  such  variations  inevitable. 
Compare  this  manual  with  your  system  instal-
lation  drawings  and  appropriate  Ransburg 
equipment  manuals  to  reconcile  such  differ-
ences. 

 
Careful study and continued use of this manual 
will  provide  a  better  understanding  of  the 
equipment  and  process,  resulting  in  more  effi-
cient operation, longer trouble-free service and 
faster,  easier  troubleshooting.  If  you  do  not 
have the manuals and safety literature for your  
Ransburg 

system, 

contact 

your 

local  

Ransburg representative or Ransburg. 

SAFETY 

  The  user 

MUST

  read  and  be  familiar 

with the Safety Section in this manual and 
the  Ransburg  safety  literature  therein 
identified.  

 

 

 

  This  manual 

MUST

  be  read  and  thor-

oughly  understood  by 

ALL

  personnel  who 

operate,  clean  or  maintain  this  equipment! 
Special care should be taken to ensure that 
the 

WARNINGS

  and  safety  requirements 

for  operating  and  servicing  the  equipment 
are  followed.  The  user  should  be  aware  of 
and  adhere  to  ALL  local  building  and  fire 
codes and ordinances as well as 

NFPA-33 

SAFETY  STANDARD,  LATEST  EDITION

prior  to  installing,  operating,  and/or  servic-
ing this equipment.  

                      

 

W A R N I N G 

                      

 

W A R N I N G 

 

The  hazards  shown  on  the  following 

pages may occur during the normal use of 
this  equipment.  Please  read  the  hazard 
chart beginning on page 2.  

Содержание RCS Series

Страница 1: ...eries A13619 00 0 3 cc rev A13620 00 0 6 cc rev A13621 00 1 8 cc rev A13635 00 3 0 cc rev IMPORTANT Before using this equipment carefully read all SAFETY PRECAUTIONS starting on page 1 and all instruc...

Страница 2: ...Positive Displacement Pump LN 9415 01 N O T E S...

Страница 3: ...ONS 7 SPECIFICATIONS 7 8 INSTALLATION 9 GENERAL INFORMATION 9 SYSTEM STARTUP 9 OPERATION 10 PRINCIPLE OF OPERATION 10 SERVICE PARTS 11 DISASSEMBLY FLUSHABLE 11 REASSEMBLY FLUSHABLE 12 PARTS LIST FLUSH...

Страница 4: ...make such variations inevitable Compare this manual with your system instal lation drawings and appropriate Ransburg equipment manuals to reconcile such differ ences Careful study and continued use o...

Страница 5: ...used for general cleaning must have a flash point at minimum of 5 C 9 F greater than the ambient temperature It is the end users responsibility to insure this condition is met Spray booth ventilation...

Страница 6: ...described in the corresponding section of the equipment manual Protection against inadvertent arcing that is capable of causing fire or explosion is lost if the current over load sensitivity is not p...

Страница 7: ...d Rubber soled insu lating shoes should not be worn Grounding straps on wrists or legs may be used to assure adequate ground contact Operators must not be wearing or carrying any ungrounded metal obje...

Страница 8: ...must be located outside Class I or II Division 1 and 2 hazardous areas in accordance with NFPA 33 and EN 50176 Turn the power supply OFF before working on the equipment Test only in areas free of flam...

Страница 9: ...The chemical re action caused by these solvents reacting with aluminum can be come violent and lead to an equipment explosion Aluminum is widely used in other spray application equipment such as mater...

Страница 10: ...with a 22 337 by pass valve provides faster color changes and minimizes solvent usage WATER BASED APPLICATIONS The DLC pumps can be used in waterborne applications overall It is highly recommended tha...

Страница 11: ...440B 440B 440B 440B Shaft Gear Material 440B 440B 440B 440B 440B 440B 440B Hardness DLC Vickers 2500 2500 2500 2500 2500 2500 2500 Working Pressure max PSI 300 300 300 300 300 300 300 Input pressure...

Страница 12: ...specified torque settings INSTALLATION RCS RESIN PUMP MOUNTED ILLUSTRATION MAX TORQUE FOR MOUNTING BOLTS 17 LB FT 23 N m Note TORQUE REQUIREMENTS AND TIGHTENING PROCEDURES HAVE THE SAME TORQUE SPECIF...

Страница 13: ...of pump generally used for the transfer and metering of liq uids The gear pump is a precision machine with extremely tight fits and tolerances and is capable of working under high differential pressur...

Страница 14: ...ide gear off of shaft 7 Pull seal 10 from front plate use seal puller or drive from opposite side Be careful not to damage the pump bore dur ing removal Please Note Driven shaft is fixed in the body a...

Страница 15: ...aft on bottom plate 4 Install middle plate 4 5 Install drive shaft and gear 6 into bot tom plate assembly 6 Install O rings 8 9 into grooves on top of plate 7 Assemble top plate 3 onto pump as sembly...

Страница 16: ...KIT CHART B BELOW 7 1 KEYWAY N A 8 2 A13790 00 O RING INCLUDED IN A13790 KIT 9 2 A13790 00 O RING INCLUDED IN A13790 KIT 10 1 22 315 SEAL RADIAL INCLUDED IN A13790 KIT SEE FIGURE 1 4 EXPLODED PUMP VIE...

Страница 17: ...it will only slide out in one direction 5 Remove the center plate 9 carefully 6 Slide drive gear off of shaft 7 Pull seal 15 from front plate use seal puller or drive from opposite side Be careful no...

Страница 18: ...nstall circlip on drive shaft closest to front plate 5 Install key 7 Slide on drive gear 5 and install second circlip 6 Install a new O ring 10 on bottom plate and top plate in appropriate O ring groo...

Страница 19: ...PLATE CENTER SEE KIT CHART A BELOW 10 2 A13791 00 O RING INCLUDED IN A13791 KIT 11 12 13 14 PLATE TOP N A 15 1 22 383 SEAL RADIAL INCLUDED IN A13791 KIT SEE FIGURE 1 2 EXPLODED PUMP VIEW NON FLUSHABL...

Страница 20: ...gear binding Maintain the fluid filters according to the instructions from the filter manufacturer If repeated disassembly and cleaning for removal of solids and particu lates occurs inspect the entir...

Страница 21: ...chase WRAPPING THE APPLICATOR ASSO CIATED VALVES AND TUBING AND SUPPORTING HARDWARE IN PLASTIC SHRINK WRAP OR ANY OTHER NON APPROVED COVERING WILL VOID THIS WARRANTY RANSBURG S ONLY OBLIGATION UNDER T...

Страница 22: ...e Street Angola Indiana 46703 9100 Telephone 260 665 8800 Fax 260 665 8516 Technical Service Assistance 320 Philips Ave Toledo Ohio 43612 1493 Telephone toll free 800 233 3366 Fax 419 470 2233 www ran...