CP-08-01
9040 Classic HV Power Supply - Maintenance
2 2
2 2
2 2
2 2
2 2
3. Press panel retaining clips on top and bottom of
switch 1SW together and push switch out of panel
from the inside.
4. Press new switch (see "Parts Identification"
section of this manual for part number) into panel
opening with terminals 1A and 2A to the bottom of
the cabinet.
5. Reconnect the four (4) quick connect terminals
to the new switch as follows:
1FU-2
1TB-N
1TB-S1
1TB-S2
From
From
From
From
From
T o
T o
T o
T o
T o
1SW-1
1SW-2
1SW-1A
1SW-2A
>
It is recommended that the four (4)
ON/OFF switch wires be tagged with
their respective terminal connections to
1SW before removing.
N O T E
N O T E
N O T E
N O T E
N O T E
AC Line Cord
AC Line Cord
AC Line Cord
AC Line Cord
AC Line Cord
1. Ensure power supply is unplugged from AC
outlet and open the cabinet door.
3. Loosen the line cord grommet on side panel
and pull damaged cord out.
4. Insert new line cord (see "Parts Identification"
section of this manual for part numbers) through
grommet and connect to 1TB as follows:
5. Tighten side panel grommet.
6. Secure cabinet door and plug power supply
back in.
Pressure Switch
Pressure Switch
Pressure Switch
Pressure Switch
Pressure Switch
1. Disconnect pressure signal input line from
pressure switch.
2. Ensure power supply is unplugged from AC
outlet and open cabinet door.
3. Remove two (2) wires from pressure switch
terminals.
4. Loosen hex nut from fitting and remove pressure
switch and fitting from the power supply.
5. Remove fitting from defective pressure switch
and install on new pressure switch (see "Parts
Identification" section of this manual for part
numbers).
6. Install new pressure switch in power supply by
securing hex nut to fitting.
7. Attach two (2) wires to the NO (normally open)
and C (common) terminals of the pressure switch
(it does not matter which one goes where). DO
NOT attach any wires to the NC terminal of the
pressure switch.
>
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS double check that the control
unit is unplugged from its AC outlet BE-
BE-
BE-
BE-
BE-
FORE
FORE
FORE
FORE
FORE working with any internal wiring.
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
!!!!!
6. Secure cabinet door and plug power supply
back in.
2. Using a screwdriver, disconnect damaged line
cord from 1TB-L1, 1TB-N, and 1TB-GROUND.
1TB-GROUND
1TB-N
1TB-L1
Line Cord Ground
Line Cord Neutral/Common
Line Cord Hot/Line
From
From
From
From
From
T o
T o
T o
T o
T o
ARCHIVE
Содержание 77070-33
Страница 2: ...CP 08 01 ARCHIVE ...
Страница 9: ...CP 08 01 6 6 6 6 6 9040 Classic HV Power Supply Safety NOTES NOTES NOTES NOTES NOTES ARCHIVE ...
Страница 19: ...CP 08 01 9040 Classic HV Power Supply Maintenance 16 16 16 16 16 NOTES NOTES NOTES NOTES NOTES ARCHIVE ...
Страница 33: ...CP 08 01 9040 Classic HV Power Supply Maintenance 30 30 30 30 30 NOTES NOTES NOTES NOTES NOTES ARCHIVE ...
Страница 39: ...CP 08 01 ARCHIVE ...